Multicenter clinical comparison of Resin-containing bottles with standard aerobic and anaerobic bottles for culture of microorganisms from blood

被引:15
作者
Lelievre, H
Gimenez, M
Vandenesch, F
Reinhardt, A
Lenhardt, D
Just, HM
Pau, M
Ausina, V
Etienne, J
机构
[1] HOSP UNIV GERMANS TRIAS I PUJOL,INST CATALA SALUT,MICROBIOL LAB,BADALONA,SPAIN
[2] KLINIKUM NORD,MICROBIOL LAB,D-90419 NURNBERG,GERMANY
关键词
D O I
10.1007/BF01708557
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
In a study comparing the Bactec 9240 (Plus Aerobic/F and Anaerobic/F bottles, containing resins; Becton Dickinson, USA) and the Vital (standard aerobic and anaerobic bottles, with no additives; bioMerieux, France) blood culture systems, 6456 sets of four bottles of 9660 blood cultures submitted were evaluated, There were 531 clinically significant isolates from 795 positive blood cultures, Of the 531 positive blood cultures, 355 were positive in both systems, 141 with the Bactec 9240 alone, and 30 with the Vital alone (p < 0.001); five were not detected by either system, The average time to detection of positive cultures for the matched sets was 10.65 h and 18.41 h by the Bactec 9240 system and the Vital system, respectively, The false-positive rate per bottle was 0.65% in the Bactec 9240 and 0.71% in the Vital, The rate of false-negative pairs (i.e., major errors) was very low (0.12% for the Bactec 9240, 0.19% for the Vital) and not significantly different between the two systems. The striking differences in recovery of microorganisms may be due to the presence of resins in the Bactec medium. However, the observed superiority of the Bactec 9240, even for patients not receiving antibiotics, suggests that resins adsorb other inhibitors present in patients' blood.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 8 条
  • [1] AVRIL JL, 1995, ANN BIOL CLIN-PARIS, V53, P21
  • [2] Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia
    Jorgensen, JH
    Mirrett, S
    McDonald, LC
    Murray, PR
    Weinstein, MP
    Fune, J
    Trippy, CW
    Masterson, M
    Reller, LB
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) : 53 - 58
  • [3] DETECTION KINETICS FOR POSITIVE BLOOD CULTURE BOTTLES BY USING THE VITAL AUTOMATED-SYSTEM
    MARCHANDIN, H
    COMPAN, B
    DEBUOCHBERG, MS
    DESPAUX, E
    PEREZ, C
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (08) : 2098 - 2101
  • [4] MCNEMAR Q, 1962, PSYCHOL STATISTICS, P224
  • [5] MULTICENTER CLINICAL-EVALUATION OF A CONTINUOUS MONITORING BLOOD CULTURE SYSTEM USING FLUORESCENT-SENSOR TECHNOLOGY (BACTEC-9240)
    NOLTE, FS
    WILLIAMS, JM
    JERRIS, RC
    MORELLO, JA
    LEITCH, CD
    MATUSHEK, S
    SCHWABE, LD
    DORIGAN, F
    KOCKA, FE
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (03) : 552 - 557
  • [6] EVALUATION OF BACTEC-9240 BLOOD CULTURE SYSTEM BY USING HIGH-VOLUME AEROBIC RESIN MEDIA
    SCHWABE, LD
    THOMSON, RB
    FLINT, KK
    KOONTZ, FP
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (09) : 2451 - 2453
  • [7] VALUE OF TERMINAL SUBCULTURES FOR BLOOD CULTURES MONITORED BY BACTEC-9240
    SHIGEI, JT
    SHIMABUKURO, JA
    PEZZLO, MT
    DELAMAZA, LM
    PETERSON, EM
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (05) : 1385 - 1388
  • [8] COMPARISON OF BACTEC-9240 AND BACT/ALERT BLOOD CULTURE SYSTEMS IN AN ADULT HOSPITAL
    SMITH, JA
    BRYCE, EA
    NGUIYEN, JH
    ROBERTS, FJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) : 1905 - 1908