Modeling and analysis of biomagnetic blood Carreau fluid flow through a stenosis artery with magnetic heat transfer: A transient study

被引:55
作者
Jamalabadi, Mohammad Yaghoub Abdollahzadeh [1 ]
Daqiqshirazi, Mohammadreza [2 ]
Nasiri, Hossein [3 ]
Safaei, Mohammad Reza [4 ,5 ]
Truong Khang Nguyen [4 ,5 ]
机构
[1] Dongguk Univ, Dept Mech Robot & Energy Engn, Seoul, South Korea
[2] Univ Tehran, Coll Engn, Sch Mech Engn, Tehran, Iran
[3] Daneshpajoohan Higher Educ Inst, Dept Mech Engn, Esfahan, Iran
[4] Ton Duc Thang Univ, Inst Computat Sci, Div Computat Phys, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
关键词
NON-NEWTONIAN BLOOD; NUMERICAL-SIMULATION; ENDOTHELIAL-CELLS; MICROPOLAR FLUID; DISTURBED FLOW; DRUG-DELIVERY; FIELD; BIFURCATION; RADIATION; DYNAMICS;
D O I
10.1371/journal.pone.0192138
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
We present a numerical investigation of tapered arteries that addresses the transient simulation of non-Newtonian bio-magnetic fluid dynamics (BFD) of blood through a stenosis artery in the presence of a transverse magnetic field. The current model is consistent with ferro-hydrodynamic (FHD) and magneto-hydrodynamic (MHD) principles. In the present work, blood in small arteries is analyzed using the Carreau-Yasuda model. The arterial wall is assumed to be fixed with cosine geometry for the stenosis. A parametric study was conducted to reveal the effects of the stenosis intensity and the Hartman number on a wide range of flow parameters, such as the flow velocity, temperature, and wall shear stress. Current findings are in a good agreement with recent findings in previous research studies. The results show that wall temperature control can keep the blood in its ideal blood temperature range (below 40 degrees C) and that a severe pressure drop occurs for blockages of more than 60 percent. Additionally, with an increase in the Ha number, a velocity drop in the blood vessel is experienced.
引用
收藏
页数:32
相关论文
共 74 条
[1]
Ferromagnetic CNT suspended H2O + Cu nanofluid analysis through composite stenosed arteries with permeable wall [J].
Akbar, Noreen Sher .
PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2015, 72 :70-76
[2]
Carreau fluid model for blood flow through a tapered artery with a stenosis [J].
Akbar, Noreen Sher ;
Nadeem, S. .
AIN SHAMS ENGINEERING JOURNAL, 2014, 5 (04) :1307-1316
[3]
Entropy Generation Analysis for a CNT Suspension Nanofluid in Plumb Ducts with Peristalsis [J].
Akbar, Noreen Sher .
ENTROPY, 2015, 17 (03) :1411-1424
[4]
Magnetic field effect on blood flow of Casson fluid in axisymmetric cylindrical tube: A fractional model [J].
Ali, Farhad ;
Sheikh, Nadeem Ahmad ;
Khan, Ilyas ;
Saqib, Muhammad .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 423 :327-336
[5]
Computational Analysis of Transient non-Newtonian Blood Flow in Magnetic Targeting Drug Delivery in Stenosed Carotid Bifurcation Artery [J].
Alimohamadi, Haleh ;
Imani, Mohsen ;
Forouzandeh, Behjat .
INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2015, 42 (02) :149-169
[6]
Transient Non-Newtonian Blood Flow under Magnetic Targeting Drug Delivery in an Aneurysm Blood Vessel with Porous Walls [J].
Alimohamadi, Haleh ;
Imani, Mohsen .
INTERNATIONAL JOURNAL FOR COMPUTATIONAL METHODS IN ENGINEERING SCIENCE & MECHANICS, 2014, 15 (06) :522-533
[7]
Finite Element Simulation of Two-Dimensional Pulsatile Blood Flow Through a Stenosed Artery in the Presence of External Magnetic Field [J].
Alimohamadi, Haleh ;
Imani, Mohsen .
INTERNATIONAL JOURNAL FOR COMPUTATIONAL METHODS IN ENGINEERING SCIENCE & MECHANICS, 2014, 15 (04) :390-400
[8]
Amornsamankul S., 2005, Int. J. Biol. Life Sci, V1, P42
[9]
[Anonymous], 2008, INT J NUMERICAL METH
[10]
[Anonymous], 1980, Numerical heat transfer and fluid flow