A comparison between office and ambulatory blood pressure measurements in renal transplant patients with chronic transplant nephropathy

被引:44
作者
Kooman, JP [1 ]
Christiaans, MHC [1 ]
Boots, JMM [1 ]
van der Sande, FM [1 ]
Leunissen, KML [1 ]
van Hooff, JP [1 ]
机构
[1] Univ Hosp Maastricht, Dept Internal Med, NL-6202 AZ Maastricht, Netherlands
关键词
renal transplantation; transplant nephropathy; ambulatory blood pressure;
D O I
10.1053/ajkd.2001.24518
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Hypertension is an important risk factor for chronic transplant nephropathy. Therapy is usually based on casual office blood pressure (BP) measurements. However, it is not well known how casual BP predicts 24-hour BP in this population. The main focus of this study is to compare casual office BP with 24-hour ambulatory BP monitoring in renal transplant recipients with signs of chronic transplant nephropathy. Moreover, in this group, the day-night BP profile was assessed. In 36 renal transplant recipients with incipient or progressive proteinuria or an increase in serum creatinine level greater than 20%, 24-hour ambulatory BP was performed. Patients were defined as a nondipper if the mean BP decreased by less than 10% during the nighttime period. The correlation between single office and 24-hour ambulatory BPs was 0.61 for systolic BP and 0.55 for diastolic BP (P < 0.001). The mean difference between 24-hour ambulatory and single office BPs was -4.2 +/- 18.6 mm Hg (range, -44 to 36 mm Hg) for systolic BP and -1.1 +/- 10.7 mm Hg (range, -34 to 27 mm Hg) for diastolic BP; 94.5% of patients were classified as nondippers. There was a significant relation between the nightly decline in mean arterial pressure and calculated creatinine clearance (r = 0.34; P < 0.05). In conclusion, in renal transplant recipients with chronic transplant nephropathy, a large difference between office and ambulatory BPs is present, with both overestimation and underestimation of 24-hour BP by office BP measurements. Moreover, a severely disturbed day-night BP rhythm was observed. In transplant recipients with compromised graft function, office BP may not reflect 24-hour BP adequately, and ambulatory BP measurements should be considered. (C) 2001 by the National Kidney Foundation, Inc.
引用
收藏
页码:1170 / 1176
页数:7
相关论文
共 22 条
[11]   BLOOD-PRESSURE DURING THE INTERDIALYTIC PERIOD IN HEMODIALYSIS-PATIENTS - ESTIMATION OF REPRESENTATIVE BLOOD-PRESSURE VALUES [J].
KOOMAN, JP ;
GLADZIWA, U ;
BOCKER, G ;
WIJNEN, JAG ;
VONBORTEL, L ;
LUIK, AJ ;
DELEEUW, PW ;
VONHOOFF, JP ;
LEUNISSEN, KML .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1992, 7 (09) :917-923
[12]   Twenty-four-hour ambulatory blood pressure profiles in pediatric patients after renal transplantation [J].
Lingens, N ;
Dobos, E ;
Witte, K ;
Busch, C ;
Lemmer, B ;
Klaus, G ;
Scharer, K .
PEDIATRIC NEPHROLOGY, 1997, 11 (01) :23-26
[13]   AMBULATORY BLOOD-PRESSURE AND LEFT-VENTRICULAR MASS IN CYCLOSPORINE-TREATED AND NON-CYCLOSPORINE-TREATED RENAL-TRANSPLANT RECIPIENTS [J].
LIPKIN, GW ;
TUCKER, B ;
GILES, M ;
RAINE, AEG .
JOURNAL OF HYPERTENSION, 1993, 11 (04) :439-442
[14]   Arterial hypertension and renal allograft survival [J].
Mange, KC ;
Cizman, B ;
Joffe, M ;
Feldman, HI .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (05) :633-638
[15]   Ambulatory blood pressure monitoring is a useful clinical tool in nephrology [J].
Mansoor, GA ;
White, WB .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (05) :591-605
[16]   Association of chronic kidney graft failure with recipient blood pressure [J].
Opelz, G ;
Wujciak, T ;
Ritz, E .
KIDNEY INTERNATIONAL, 1998, 53 (01) :217-222
[17]  
Peixoto A J, 1999, Blood Press Monit, V4, P217
[18]   Hypertension and allograft nephropathy - cause, consequence, or both? [J].
Schindler, R ;
Tanriver, Y ;
Frei, U .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (01) :8-10
[19]   Abnormal 24-hour blood pressure patterns in children after renal transplantation [J].
Sorof, JF ;
Poffenbarger, T ;
Portman, R .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (04) :681-686
[20]  
Staessen J A, 1999, Blood Press Monit, V4, P127