Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair

被引:106
作者
Torsello, Giovanni [1 ,2 ]
Troisi, Nicola [1 ,2 ]
Donas, Konstantinos P. [1 ]
Austermann, Martin [2 ]
机构
[1] Univ Hosp, Ctr Vasc & Endovasc Surg, D-48149 Munster, Germany
[2] St Franziskus Hosp, Dept Vasc Surg, Milan, Italy
关键词
NECK ANGULATION; EXPERIENCE; ANATOMY; DEVICE;
D O I
10.1016/j.jvs.2010.12.062
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background: This study evaluated the early and intermediate results of endovascular aortic aneurysm repair (EVAR) using the Endurant stent graft (Medtronic Cardiovascular, Santa Rosa, Calif) in patients treated according to device-specific instructions for use (IFU) for the proximal aortic neck compared with those obtained in patients treated in an off-label (OL) situation. Methods:Between November 2007 and March 2010, 177 consecutive patients with abdominal aortic aneurysms (AAAs) were treated with the Endurant stent graft at our centers. The IFU for the Endurant stent graft included a proximal neck of 15 mm in length and <750 degrees of angulation or 10 mm of neck length and <600 degrees of angulation. The 121 patients (68.4%) operated on according to IFU were compared with 56 (31.6%) who underwent EVAR in OL circumstances to evaluate significant differences in demographics, intraoperative technical factors, and early (30 days) and intermediate outcomes (1 year). Results: Significantly more patients were aged >80 years in the OL group (37.5% vs 19%, P = .008), and they also had larger aneurysms (59 +/- 10.6 vs 55.9 +/- 10.8 nun, P = .05) and required a longer procedure time (69.3 +/- 27.2 vs 60.8 +/- 20.4 minutes, P = .02). At 30 days, the risk of type I endoleak was higher in the OL group (2 patients, 3.6% vs 0 in IFU), but this did not reach statistical significance (P = .09). The two groups were similar in rates of perioperative mortality, major morbidity, technical success, clinical success, complications, and reinterventions. At 1 year, there were no differences between the two groups in survival, freedom from any device-related reinterventions, and freedom from graft thrombosis. Estimated 1-year freedom from type I endoleak was 100% in the IFU group vs 93.3% in the OL group (P = .01). Conclusions: In patients with both normal and complex anatomy of the proximal aortic neck, the Endurant stent graft obtained acceptable results, with no difference in survival, morbidity, or reinterventions. However, there was a greater risk of type I endoleak when OL indications were applied. Longer term follow-up is required to evaluate the effectiveness of this endograft in preventing late aneurysm-related complications. (J Vase Surg 2011;54:300-6.)
引用
收藏
页码:300 / 306
页数:7
相关论文
共 28 条
[1]
Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): An anatomic and device-specific analysis [J].
Abbruzzese, Thomas A. ;
Kwolck, Christopher J. ;
Brewster, David C. ;
Chung, Thomas K. ;
Kang, Jeanwan ;
Conrad, Mark F. ;
LaMuraglia, Glenn M. ;
Cambria, Richard P. .
JOURNAL OF VASCULAR SURGERY, 2008, 48 (01) :19-28
[2]
The correlation of aortic neck length to early and late outcomes in endovascular aneurysm repair patients [J].
AbuRahma, Ali F. ;
Campbell, John ;
Stone, Patrick A. ;
Nanjundappa, Aravinda ;
Jain, Akhilesh ;
Dean, L. Scott ;
Habib, Joseph ;
Keiffer, Tammi ;
Emmett, Mary .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (04) :738-748
[3]
Factors affecting survival after endovascular aneurysm repair: Results from a population based audit [J].
Boult, M. ;
Maddern, G. ;
Barnes, M. ;
Fitridge, R. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2007, 34 (02) :156-162
[4]
Impact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair [J].
Carpenter, JP ;
Baum, RA ;
Barker, CF ;
Golden, MA ;
Mitchell, ME ;
Velazquez, OC ;
Fairman, RM .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (06) :1050-1054
[5]
Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? [J].
Dillavou, ED ;
Muluk, SC ;
Rhee, RY ;
Tzeng, E ;
Woody, JD ;
Gupta, N ;
Makaroun, MS .
JOURNAL OF VASCULAR SURGERY, 2003, 38 (04) :657-663
[6]
Vascular Endostapling: New Concept for Endovascular Fixation of Aortic Stent-Grafts [J].
Donas, Konstantinos P. ;
Kafetzakis, Alexandros ;
Umscheid, Thomas ;
Tessarek, Joerg ;
Torsello, Giovanni .
JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) :499-503
[7]
Effect of challenging neck anatomy on mid-term migration rates in AneuRx endografts [J].
Fulton, Joseph J. ;
Farber, Mark A. ;
Sanchez, Luis A. ;
Godshall, Christopher J. ;
Marston, William A. ;
Mendes, Robert ;
Rubin, Brian G. ;
Sicard, Gregorio A. ;
Keagy, Blair A. .
JOURNAL OF VASCULAR SURGERY, 2006, 44 (05) :932-937
[8]
Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial [J].
Greenhalgh, RM ;
Brown, LC ;
Epstein, D ;
Kwong, GPS ;
Powell, JT ;
Sculpher, MJ ;
Thompson, SG .
LANCET, 2005, 365 (9478) :2179-2186
[9]
Endovascular Repair of Aortic Aneurysm in Patients Physically Ineligible for Open Repair [J].
Greenhalgh, Roger M. ;
Brown, Louise C. ;
Powell, Janet T. ;
Thompson, Simon G. ;
Epstein, David .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (20) :1872-1880
[10]
Ionizing radiation absorption of vascular surgeons during endovascular procedures [J].
Ho, Pei ;
Cheng, Stephen W. K. ;
Wu, P. M. ;
Ting, Albert C. W. ;
Poon, Jensen T. C. ;
Cheng, Clement K. M. ;
Mok, Joseph H. M. ;
Tsang, M. S. .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (03) :455-459