Towards wide-field retinal imaging with adaptive optics

被引:51
作者
Glanc, M [1 ]
Gendron, E
Lacombe, F
Lafaille, D
Le Gargasson, JF
Léna, P
机构
[1] Observ Paris, Lab Etud Spatiales & Instrumentat Astrophys, F-92195 Meudon, France
[2] Univ Paris 07, CNRS, UMR 8632, F-92195 Meudon, France
[3] Univ Paris 07, INSERM, Unite 483, Lab Biophys Vis, F-75010 Paris, France
关键词
adaptive optics; physiological optics;
D O I
10.1016/j.optcom.2003.11.020
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In vivo imaging of the retina on humans by means of adaptive optics can lead to a significant gain in resolution. We demonstrate the realization and use of a system made of a Shack-Hartmann wavefront sensor carefully matched to a 13-actuator bimorph deformable mirror sensor, operating at a closed loop frequency of 70 Hz at lambda = 835 nm. Even with this simple but optimized system with 12 degrees of freedom, correcting only aberrations of moderate orders, we routinely and systematically obtain retinal images containing spatial information up to half the diffraction limit frequency of a dilated (7 mm) iris at a lambda = 550 nm wavelength (1.6 mum diffraction spot size). Signal-to-noise ratio on the images is limited by eye safety constraints, but is sufficient to reach the high-frequency information on single, short-exposure (7 ms) images, which clearly show individual cones and capillary details. Correction is highly depending on proper centering of the eye, achieved with an active target. Focusing through the retina is possible with a reduced depth of focus. Variability of moderate order aberrations among dilated subjects has been observed. Using an image fitting algorithm, individual images are used to build a wider field corrected image of the retina (approximate to3degrees), possibly useful for diagnosis and microcirculation analysis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 238
页数:14
相关论文
共 29 条
[1]  
American National Standard for Safe Use of Lasers, Z1361 ANSI
[2]   High-resolution imaging of the human retina with a Fourier deconvolution technique [J].
Catlin, D ;
Dainty, C .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (08) :1515-1523
[3]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[4]  
DAVIES N, 2003, OPTOM VIS SCI, V80
[5]   Benefit of higher closed-loop bandwidths in ocular adaptive optics [J].
Diaz-Santana, L ;
Torti, C ;
Munro, I ;
Gasson, P ;
Dainty, C .
OPTICS EXPRESS, 2003, 11 (20) :2597-2605
[6]   Membrane deformable mirror for adaptive optics:: performance limits in visual optics [J].
Fernández, EJ ;
Artal, P .
OPTICS EXPRESS, 2003, 11 (09) :1056-1069
[7]   Closed-loop adaptive optics in the human eye [J].
Fernández, EJ ;
Iglesias, I ;
Artal, P .
OPTICS LETTERS, 2001, 26 (10) :746-748
[8]  
GLANC M, 2000, ADAPTIVE OPTICS IND
[9]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[10]   THE SPATIAL-RESOLUTION CAPACITY OF HUMAN FOVEAL RETINA [J].
HIRSCH, J ;
CURCIO, CA .
VISION RESEARCH, 1989, 29 (09) :1095-&