New fully portable instrument for the versatile determination of cations and anions by capillary electrophoresis with contactless conductivity detection

被引:103
作者
Kuban, Pavel
Nguyen, Huong Thi Anh
Macka, Mirek
Haddad, Paul R.
Hauser, Peter C.
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
[2] Acad Sci Czech Republic, Inst Analyt Chem, CS-61142 Brno, Czech Republic
[3] Hanoi Univ Sci, Ctr Environm Technol & Sustainable Dev, Hanoi, Vietnam
[4] Univ Tasmania, Sch Chem, Fac Sci Engn & Technol, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[5] Dublin City Univ, Dept Chem Sci, Dublin 9, Ireland
关键词
capillary electrophoresis; contactless conductivity detection; portable instrument; environmental analyses; arsenic; heavy metals; inorganic ions;
D O I
10.1002/elan.200703908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new portable capillary electrophoresis instrument with capacitively coupled contactless conductivity detection was developed and optimized for the sensitive field measurements of ionic compounds in environmental samples. It is powered by batteries and the high voltage modules are capable of delivering up to 15 kV at either polarity for more than one working day. Inorganic cations and anions, including ions of heavy metals and arsenate, could be determined with detection limits in the range from about 0.2 to 1 mu M. The instrument was field tested in a remote region of Tasmania and nitrite and ammonium could be determined on-site at concentrations as low as 10 ppb in presence of other common inorganic ions at concentrations which were 2 to 3 orders of magnitude higher.
引用
收藏
页码:2059 / 2065
页数:7
相关论文
共 27 条
[1]   Field-portable flow-injection analysers for monitoring of air and water pollution [J].
Alexander, PW ;
DiBenedetto, LT ;
Dimitrakopoulos, T ;
Hibbert, DB ;
Ngila, JC ;
Sequeira, M ;
Shiels, D .
TALANTA, 1996, 43 (06) :915-925
[2]   Compact, field-portable capillary ion chromatograph [J].
Boring, CB ;
Dasgupta, PK ;
Sjögren, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 804 (1-2) :45-54
[3]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[4]   On-chip potential gradient detection with a portable capillary electrophoresis system [J].
Feng, HT ;
Wei, HP ;
Li, SFY .
ELECTROPHORESIS, 2004, 25 (06) :909-913
[5]   Conductivity detection for conventional and miniaturised capillary electrophoresis systems [J].
Guijt, RM ;
Evenhuis, CJ ;
Macka, M ;
Haddad, PR .
ELECTROPHORESIS, 2004, 25 (23-24) :4032-4057
[6]   Recent advances in portable X-ray fluorescence spectrometry [J].
Hou, XD ;
He, YH ;
Jones, BT .
APPLIED SPECTROSCOPY REVIEWS, 2004, 39 (01) :1-25
[7]   Ion-chromatographic determination of fluoride ions in atmospheric precipitates and natural waters [J].
Kalyakina, OP ;
Dolgonosov, AM .
JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (10) :951-953
[8]   Field-portable capillary electrophoresis instrument with potentiometric and amperometric detection [J].
Kappes, T ;
Schnierle, P ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :77-82
[9]   Portable capillary electrophoresis instrument with potentiometric detection [J].
Kappes, T ;
Hauser, PC .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :325-329
[10]   Portable capillary electrophoresis instrument with amperometric, potentiometric and conductometric detection [J].
Kappes, T ;
Galliker, B ;
Schwarz, MA ;
Hauser, PC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :133-139