In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging

被引:38
作者
Sharma, S
Ensley, AE
Hopkins, K
Chatzimavroudis, GP
Healy, TM
Tam, VKH
Kanter, KR
Yoganathan, AP
机构
[1] Childrens Heart Ctr, Atlanta, GA 30329 USA
[2] Cleveland State Univ, Dept Chem Engn, Cleveland, OH 44115 USA
[3] Georgia Inst Technol, Sch Biomed Engn, Atlanta, GA 30332 USA
[4] Emory Univ, Sch Med, Dept Cardiothorac Surg, Atlanta, GA USA
关键词
D O I
10.1016/S0003-4975(00)02517-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The total cavopulmonary connection (TCPC) design continues to be refined on the basis of now analysis at the connection site. These refinements are of importance for myocardial energy conservation in the univentricular supported circulation. In vivo magnetic resonance phase contrast imaging provides semiquantitative now visualization information. The purpose of this study was to understand the in vivo TCPC flow characteristics obtained by magnetic resonance phase contrast imaging and compare the results with our previous in vitro TCPC flow experiments in an effort to further refine TCPC surgical design. Methods. Twelve patients with TCPC underwent sedated three-dimensional, multislice magnetic resonance phase contrast imaging. Seven patients had intraatrial lateral tunnel TCPC and 5 had extracardiac TCPC. Results. In all patients in both groups a disordered now pattern was observed in the inferior caval portion of the TCPC. mow at the TCPC site appeared to be determined by connection geometry, being streamlined at the superior vena cava-pulmonary junction when the superior vena cava was offset and flared toward the left pulmonary artery. Without caval offset, intense swirling and dominance of superior vena caval flow was observed. In TCPC with bilateral superior vena cavae, the flow patterns observed included secondary vortices, a central stagnation point, and influx of the superior vena cava flow into the inferior caval conduit. A comparative analysis of in vivo flow and our previous in vitro now data from glass model prototypes of TCPC demonstrated significant similarities in now disturbances. Three-dimensional magnetic resonance phase contrast imaging in multiple coronal planes enabled a comprehensive semiquantitative now analysis. The data are presented in traditional instantaneous images and in animated format for interactive display of the now dynamics. Conclusions. Flow in the inferior caval portion of the TCPC is disordered, and the TCPC geometry determines flow characteristics. (C) 2001 by The Society of Thoracic Surgeons.
引用
收藏
页码:889 / 898
页数:10
相关论文
共 19 条
[1]   In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging [J].
Be'eri, E ;
Maier, SE ;
Landzberg, MJ ;
Chung, T ;
Geva, T .
CIRCULATION, 1998, 98 (25) :2873-2882
[2]   BAFFLE FENESTRATION WITH SUBSEQUENT TRANSCATHETER CLOSURE - MODIFICATION OF THE FONTAN OPERATION FOR PATIENTS AT INCREASED RISK [J].
BRIDGES, ND ;
LOCK, JE ;
CASTANEDA, AR .
CIRCULATION, 1990, 82 (05) :1681-1689
[3]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[4]   Toward designing the optimal total cavopulmonary connection: An in vitro study [J].
Ensley, AE ;
Lynch, P ;
Chatzimavroudis, GP ;
Lucas, C ;
Sharma, S ;
Yoganathan, AP .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1384-1390
[5]   The mature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the Fontan operation [J].
Fogel, MA ;
Weinberg, PM ;
Hoydu, A ;
Hubbard, A ;
Rychik, J ;
Jacobs, M ;
Fellows, KE ;
Haselgrove, J .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (06) :1032-1041
[6]  
GALE AW, 1979, J THORAC CARDIOV SUR, V78, P831
[7]  
HEALY TM, 1999, 1999 ASME BIOENG C B
[8]  
Hsia TY, 1999, CIRCULATION, V100, P671
[9]   Hemodynamics of the Fontan connection: An in-vitro study [J].
Kim, YH ;
Walker, PG ;
Fontaine, AA ;
Panchal, S ;
Ensley, AE ;
Oshinski, J ;
Sharma, S ;
Ha, B ;
Lucas, CL ;
Yoganathan, AP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04) :423-428
[10]   MODIFICATION OF THE FONTAN PROCEDURE - SUPERIOR VENA-CAVA TO LEFT PULMONARY-ARTERY CONNECTION AND INFERIOR VENA-CAVA TO RIGHT PULMONARY-ARTERY CONNECTION WITH ADJUSTABLE ATRIAL SEPTAL-DEFECT [J].
LAKS, H ;
ARDEHALI, A ;
GRANT, PW ;
PERMUT, L ;
AHARON, A ;
KUHN, M ;
ISABELJONES, J ;
GALINDO, A .
CIRCULATION, 1995, 91 (12) :2943-2947