Evaluation of a New Software Version of the FloTrac/Vigileo (Version 3.02) and a Comparison with Previous Data in Cirrhotic Patients Undergoing Liver Transplant Surgery

被引:94
作者
Biancofiore, Gianni [1 ]
Critchley, Lester A. H. [2 ]
Lee, Anna [2 ]
Yang, Xiao-xing [2 ]
Bindi, Lucia M. [1 ]
Esposito, Massimo [1 ]
Bisa, Massimo [1 ]
Meacci, Luca [1 ]
Mozzo, Roberto [1 ]
Filipponi, Franco [1 ]
机构
[1] Osped Cisanello, Azienda Osped Univ Pisana, Pisa, Italy
[2] Chinese Univ Hong Kong, Dept Anaesthesia & Intens Care, Prince Wales Hosp, Shatin, Hong Kong, Peoples R China
关键词
ARTERIAL-PRESSURE WAVE; CARDIAC-OUTPUT; FORM ANALYSIS; THERMODILUTION; PRECISION; AGREEMENT; CATHETERS; ALGORITHM; MONITORS; SYSTEM;
D O I
10.1213/ANE.0b013e31822401b2
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
BACKGROUND: Reliable cardiac output monitoring is particularly useful in the cirrhotic patient undergoing liver transplant surgery, because cirrhosis of the liver is associated with a vasodilated and high output state, known as cirrhotic cardiomyopathy, that challenges the reliability of pulse contour cardiac output technology. The contractility of the ventricle in cirrhosis is impaired, which is tolerated even though the ejection fraction and cardiac output are elevated because of the low peripheral resistance. However, during surgery the cirrhotic patient can decompensate because of the physiological changes and stress of surgery. Recently, we showed that the FloTrac/Vigileo (TM) failed to perform in cirrhotic patients undergoing transplant surgery. In response, the company upgraded their software. Therefore, we have assessed the accuracy and reliability of this new third-generation (version 3.02) FloTrac/Vigileo algorithm software in the same setting. METHODS: The cardiac index was measured simultaneously by single-bolus thermodilution (CITD), using a pulmonary artery catheter, and pulse contour analysis, using the FloTrac/Vigileo (CIV). Readings were made at 10 time points during and after liver transplant surgery in 21 patients. Comparisons with data from our 2009 study, which used second-generation (version 01.10) software, were also made. RESULTS: Our new data show that version 3.02 software significantly reduced the adverse effect on pulse contour cardiac output reading bias in low peripheral resistance states, and thus improves the overall precision and trending ability of the system. Regression analysis between CITD and CIV showed that the correlation was moderate (r = 0.67, 95% confidence interval, 0.40 to 0.86). The Bland and Altman analysis showed that bias was 0.4 L.min(-1).m(-2), and the percentage error was 52% (95% confidence interval, 49% to 55%). Trending ability of the new software also was improved but was still well below the current benchmarks. CONCLUSION: The new software (version 3.02) provided substantial improvements over the previous versions with better overall precision and trending ability. Further algorithm refinements will increase this technology's reliability to be extensively used in the highly complex setting of cirrhotic patients undergoing liver transplantation. (Anesth Analg 2011; 113: 515-22)
引用
收藏
页码:515 / 522
页数:8
相关论文
共 24 条
[1]
Fast track in liver transplantation:: 5 years' experience [J].
Biancofiore, G ;
Bindi, ML ;
Romanelli, AM ;
Boldrini, A ;
Bisà, M ;
Esposito, M ;
Urbani, L ;
Catalano, G ;
Mosca, F ;
Filipponi, E .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (08) :584-590
[2]
Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery [J].
Biancofiore, G. ;
Critchley, L. A. H. ;
Lee, A. ;
Bindi, L. ;
Bisa, M. ;
Esposito, M. ;
Meacci, L. ;
Mozzo, R. ;
DeSimone, P. ;
Urbani, L. ;
Filipponi, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :47-54
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Carstensen B., Int J Biostat, DOI DOI 10.2202/1557-4679.1107
[5]
Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)
[6]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[7]
A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output [J].
Critchley, Lester A. ;
Lee, Anna ;
Ho, Anthony M. -H. .
ANESTHESIA AND ANALGESIA, 2010, 111 (05) :1180-1192
[8]
6/2/06 Perioperative Assessment of the Cardiovascular System in ESLD and Transplantation [J].
De Wolf, Andre M. .
INTERNATIONAL ANESTHESIOLOGY CLINICS, 2006, 44 (04) :59-78
[9]
Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial [J].
Harvey, S ;
Harrison, DA ;
Singer, M ;
Ashcroft, J ;
Jones, CM ;
Elbourne, D ;
Brampton, W ;
Williams, D ;
Young, D ;
Rowan, K .
LANCET, 2005, 366 (9484) :472-477
[10]
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients [J].
Jansen, JRC ;
Schreuder, JJ ;
Mulier, JP ;
Smith, NT ;
Settels, JJ ;
Wesseling, KH .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) :212-222