Absolute Calibration of an Ashtech Z12-T GPS Receiver

被引:45
作者
Petit, Gerard [1 ]
Jiang, Zhiheng [1 ]
White, Joe [2 ]
Beard, Ronald [2 ]
Powers, Edward [3 ]
机构
[1] BIPM, Pavil Breteuil, F-92312 Sevres, France
[2] US Naval Res Lab, Washington, DC USA
[3] US Naval Observ, Washington, DC 20392 USA
基金
澳大利亚研究理事会;
关键词
Global positioning system - Uncertainty analysis - Budget control;
D O I
10.1007/PL00012865
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Dual-frequency carrier phase and code measurements from geodetic type receivers are a promising tool for frequency and time transfer. In order to use them for clock comparisons, all instrumental delays should be calibrated. We have carried out the calibration of one such receiver, an Ashtech Z12-T type, by two different methods: first, by absolute calibration using a GPS simulator; second, by differential calibration with respect to a time transfer receiver that had previously been calibrated. We present the experimental set-ups and the results of the two experiments and estimate the uncertainty budget. An ultimate uncertainty of order 1 ns in the absolute calibration seems to be attainable. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 5 条
[1]  
Brad J, 1995, P 17 BIENN GUID TEST, P316
[2]  
Petit G., 1999, Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313), P235, DOI 10.1109/FREQ.1999.840750
[3]   Use of GPS ASHTECH Z12T receivers for accurate time and frequency comparisons [J].
Petit, G ;
Thomas, C ;
Jiang, ZH ;
Uhrich, P ;
Taris, F .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (04) :941-949
[4]  
Petit G., 2000, P 14 EUR FREQ TIM FO, P40