A brief review of test methodologies for surface-engineered biomedical implant alloys

被引:51
作者
Dearnley, PA [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
total joint replacements; surface engineering; biomedical implant alloys;
D O I
10.1016/j.surfcoat.2004.10.067
中图分类号
TB3 [工程材料学];
学科分类号
0805 [材料科学与工程]; 080502 [材料学];
摘要
Surface engineering opens up very many exciting opportunities for new designs of bio-medical implant devices like total joint replacements (TJRs). The development of new bearing surface materials for such devices, however, is a very slow process. This is due to the longevity of in vitro wear tests, biocompatibility studies, clinical trials and final adoption. Given the diversity of new bearing surface materials that modem surface engineering can make possible, there is a clear need to develop valid and rapid screening tests. A brief review of possible accelerated test methods, developed at Leeds, is presented. The tests are designed to evaluate tolerance to: (i) mechanical (third body abrasion) damage; (ii) corrosion and; (iii) corrosion-wear. By referring to specific investigations throughout, the scope of such tests is fully illustrated. It Is shown that both mechanical and chemical attributes for a given surface engineering design are important in the realisation of the overall goal of improved bearing surfaces for TJRs. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 14 条
[1]
Dahm K.L., 2000, THINNING FILMS TRIBO, P155
[2]
On the nature, properties and wear response of s-phase (nitrogen-alloyed stainless steel) coatings on AISI 316L [J].
Dahm, KL ;
Dearnley, PA .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2000, 214 (L4) :181-198
[3]
Dahm L., 1995, SURF ENG, V11, P138, DOI [10.1179/sur.1995.11.2.138., DOI 10.1179/SUR.1995.11.2.138]
[4]
Corrosion-wear mechanisms of hard coated austenitic 316L stainless steels [J].
Dearnley, PA ;
Aldrich-Smith, G .
WEAR, 2004, 256 (05) :491-499
[5]
The corrosion-wear behaviour of thermally oxidised CP-Ti and Ti-6Al-4V [J].
Dearnley, PA ;
Dahm, KL ;
Çimenoglu, H .
WEAR, 2004, 256 (05) :469-479
[7]
Wear analysis of a retrieved hip implant with titanium nitride coating [J].
Harman, MK ;
Banks, SA ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (08) :938-945
[8]
Corrosion response of surface engineered titanium alloys damaged by prior abrasion [J].
Komotori, J ;
Lee, BJ ;
Dong, H ;
Dearnley, PA .
WEAR, 2001, 251 (PART 2) :1239-1249
[9]
Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head [J].
Minakawa, H ;
Stone, MH ;
Wroblewski, BM ;
Lancaster, JG ;
Ingham, E ;
Fisher, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :894-899
[10]
NASSER S, 1990, CLIN ORTHOP RELAT R, P171