Ion- and substrate-selective optode membranes and optical detection modes

被引:16
作者
SpichigerKeller, UE
机构
[1] Ctr. Chem. Sensors/Biosensors B., Swiss Fed. Institute of Technology, CH-8005 Zürich
关键词
ATR measurements; bioprocess monitoring; diluted blood plasma; ethanol-selective optode membranes; ion-selective optode membranes; refractive-index changes;
D O I
10.1016/S0925-4005(97)80173-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A brief overview covering the state-of-the-art of ion-selective bulk optode membranes and their characteristics is given in the first part. Detection principles involving attenuated total reflection (ATR) measurements and measurements of refractive-index changes are reviewed. In contrast to ion-selective optodes where an indicator is coupled to the ion-exchange reaction, chemical host-guest interactions for neutral analytes, where the chemically reactive ligand is chromogenic, are discussed. In the second par?, an alcohol-selective optode membrane and its application in continuous ethanol monitoring is presented. The ethanol-sensitive membrane is used to monitor ethanol in the vapour phase of a bioreactor. Data derived from determining ethanol using the optode membrane are compared to ethanol concentrations in the liquid phase of the reactor filling by using a reference method (distillation and density measurements) simultaneously, The data are analysed by first-order linear regression (R-2 = 0.935). The repeated use of a pair of optode membranes for six different fermentation runs shows, first, the reversible response behaviour of the membranes; secondly, reproducible starting values of the membrane absorbance at 305 nm wavelength; thirdly, a lifetime of the membranes of more than six days when analysing the vapour phase; fourthly, for each new batch of fermentation, a different but typical production rate of ethanol, which minored the production rate of the yeast cells, is monitored. This might well be the first demonstration of the feasibility of using a chemical sensor for continuous monitoring in biotechnology, References for preliminary studies on host-guest interactions of diols and oligools, such as catechol, fructose and glucose, with phenylboronic acid derivatives are provided.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 40 条
[1]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[2]   LIPOPHILICITY OF TETRAPHENYLBORATE DERIVATIVES AS ANIONIC SITES IN NEUTRAL CARRIER-BASED SOLVENT POLYMERIC MEMBRANES AND LIFETIME OF CORRESPONDING ION-SELECTIVE ELECTROCHEMICAL AND OPTICAL SENSORS [J].
BAKKER, E ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :7-17
[3]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[4]   ANION SELECTIVITIES OF TRIFLUOROACETOPHENONE DERIVATIVES AS NEUTRAL IONOPHORES IN SOLVENT-POLYMERIC MEMBRANES [J].
BEHRINGER, C ;
LEHMANN, B ;
HAUG, JP ;
SEILER, K ;
MORF, WE ;
HARTMAN, K ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :41-47
[5]  
CHARLTON SC, 1982, CLIN CHEM, V28, P1857
[6]  
Citterio D, 1996, FRESEN J ANAL CHEM, V354, P836
[7]   LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS [J].
DINTEN, O ;
SPICHIGER, UE ;
CHANIOTAKIS, N ;
GEHRIG, P ;
RUSTERHOLZ, B ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :596-603
[8]   PLASTICIZERS FOR LIQUID POLYMERIC MEMBRANES OF ION-SELECTIVE CHEMICAL SENSORS [J].
EUGSTER, R ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
AEBERSOLD, B ;
PEDRAZZA, U ;
RUEGG, D ;
SCHMID, A ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1994, 289 (01) :1-13
[9]   INTEGRATED OPTICAL SENSORS BASED ON REFRACTOMETRY OF ION-SELECTIVE MEMBRANES [J].
FREINER, D ;
KUNZ, RE ;
CITTERIO, D ;
SPICHIGER, UE ;
GALE, MT .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) :277-285
[10]  
Freiner D., 1993, P SPIE P SPIE, V2085, P124