Quantitative determination of pioglitazone in human serum by direct-injection high-performance liquid chromatography mass spectrometry and its application to a bioequivalence study

被引:63
作者
Xue, YJ
Turner, KC
Meeker, JB
Pursley, J
Arnold, M
Unger, S
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Pharmaceut Candidate Optimizat, New Brunswick, NJ 08903 USA
[2] Bristol Myers Squibb Co, Pharmaceut Res Inst, Clin Discovery, Princeton, NJ 08543 USA
[3] Bristol Myers Squibb Co, Pharmaceut Res Inst, Biostat & Programming, Princeton, NJ 08543 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 795卷 / 02期
关键词
bioequivalence study; pioglitazone;
D O I
10.1016/S1570-0232(03)00575-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 mul portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis(R) HLB column (1 mm x 50 mm, 30 mum) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 mum). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x(2)) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degreesC. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos(R) formulation (encapsulated 15 mg tablet) and an Actos(R) 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos(R) 15 mg tablet. (C) 2003 Elsevier B.V All rights reserved.
引用
收藏
页码:215 / 226
页数:12
相关论文
共 34 条
[1]  
[Anonymous], 2000, PHYS DESK REF, p[3088, 3094]
[2]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[3]  
2-Z
[4]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[5]   COLUMN-SWITCHING TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS IN BIOLOGICAL SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02) :177-190
[6]  
Clarke S.D., 1996, PHARM SCI, V2, P203
[7]   PURIFICATION AND ANALYSIS OF DRUG RESIDUES IN URINE SAMPLES BY ONLINE IMMUNOAFFINITY CHROMATOGRAPHY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CONTINUOUS-FLOW FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
DAVOLI, E ;
FANELLI, R ;
BAGNATI, R .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2679-2685
[8]  
Ding JM, 1999, RAPID COMMUN MASS SP, V13, P2151, DOI 10.1002/(SICI)1097-0231(19991115)13:21<2151::AID-RCM767>3.0.CO
[9]  
2-E
[10]   DETERMINATION OF METHANDROSTENOLONE AND ITS METABOLITES IN EQUINE PLASMA AND URINE BY COUPLED-COLUMN LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION AND CONFIRMATION BY TANDEM MASS-SPECTROMETRY [J].
EDLUND, PO ;
BOWERS, L ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (02) :341-356