Comparison of inversion-recovery gradient- and spin-echo and fast spin-echo techniques in the detection and characterization of liver lesions

被引:7
作者
Pijl, MEJ
Wasser, MNJM
van Meerten, ELV
Gratama, JWC
van de Velde, CJH
Hermans, J
Elevelt, A
Bloem, JL
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 AA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Surg Oncol, NL-2333 AA Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Med Stat, NL-2333 AA Leiden, Netherlands
[4] Philips Med Syst, Dept MR Clin Sci, Best, Netherlands
关键词
liver neoplasms; diagnosis; MR; magnetic resonance (MR); pulse sequences;
D O I
10.1148/radiology.209.2.9807569
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare respiratory-triggered inversion-recovery (IR) gradient- and spin-echo (GRASE) magnetic resonance (MR) imaging with respiratory-triggered T2-weighted fast spin-echo (SE) imaging in the diagnosis of liver metastases. MATERIALS AND METHODS: In this prospective study, two radiologists independently identified focal hepatic lesions on respiratory-triggered IR GRASE and respiratory-triggered fast SE MR images in 28 consecutive patients with 186 (135 malignant and 51 benign) proved lesions. A combination of findings at surgery, intraoperative ultrasonography (US), and histologic examination served as the standard of reference, Contrast-to-noise ratios (CNRs) were obtained from 86 lesions larger than 10 mm. RESULTS: The sensitivity in the detection of liver metastases was, independent of lesion size and observer, higher for IR CRASE imaging (55%) than for fast SE imaging (44%-50%) (observer 1, P = .014; observer 2, P = .21). Confidence levels with IR GRASE imaging were higher, but not significantly so, than those with fast SE imaging (P < .098). Both observers characterized liver lesions better with IR GRASE than with fast SE imaging (observer, P = .04; observer 2, P = .48). The metastasis-liver CNR was significantly higher (P = .012)with IR GRASE imaging. CONCLUSION: The respiratory-triggered IR CRASE sequence is a fast alternative to the respiratory-triggered fast SE sequence in the evaluation of suspected liver metastases.
引用
收藏
页码:427 / 434
页数:8
相关论文
共 19 条
[1]   SURGICAL ANATOMY AND ANATOMICAL SURGERY OF THE LIVER [J].
BISMUTH, H .
WORLD JOURNAL OF SURGERY, 1982, 6 (01) :3-9
[2]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[3]   GRASE (GRADIENT-ECHO AND SPIN-ECHO) MR IMAGING - A NEW FAST CLINICAL IMAGING TECHNIQUE [J].
FEINBERG, DA ;
OSHIO, K .
RADIOLOGY, 1991, 181 (02) :597-602
[4]   GRASE IMPROVES SPATIAL-RESOLUTION IN SINGLE-SHOT IMAGING [J].
FEINBERG, DA ;
KIEFER, B ;
JOHNSON, G .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :529-533
[5]   DETECTION OF LIVER METASTASES - COMPARISON OF SUPERPARAMAGNETIC IRON OXIDE-ENHANCED AND UNENHANCED MR-IMAGING ART 1.5 T WITH DYNAMIC CT, INTRAOPERATIVE US, AND PERCUTANEOUS US [J].
HAGSPIEL, KD ;
NEIDL, KFW ;
EICHENBERGER, AC ;
WEDER, W ;
MARINCEK, B .
RADIOLOGY, 1995, 196 (02) :471-478
[6]   Liver metastases: Improved detection with dynamic gadolinium-enhanced MR imaging? [J].
Hamm, B ;
Mahfouz, AE ;
Taupitz, M ;
Mitchell, DG ;
Nelson, R ;
Halpern, E ;
Speidel, A ;
Wolf, KJ ;
Saini, S .
RADIOLOGY, 1997, 202 (03) :677-682
[7]  
HENDRICK RE, 1993, MRI PRINCIPLES ARTIF, P2
[8]   Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T [J].
Jung, G ;
Krahe, T ;
Kugel, H ;
Gieseke, J ;
Hahn, U ;
Walter, C ;
Lackner, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :341-347
[9]   Motion suppression in MR imaging of the liver: Comparison of respiratory-triggered and nontriggered fast spin-echo sequences [J].
Low, RN ;
Alzate, GD ;
Shimakawa, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) :225-231
[10]   HYBRID RARE - IMPLEMENTATIONS FOR ABDOMINAL MR-IMAGING [J].
MITCHELL, DG ;
OUTWATER, EK ;
VINITSKI, S .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :109-117