Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T
liver;
neoplasms;
magnetic resonance imaging;
pulse sequences;
techniques;
D O I:
10.1097/00004728-199705000-00002
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: Our goal was to investigate the value of T2-weighted fast SE (FSE) sequences, FSE sequences with shortened echo spacing (UFSE), combined gradient and spin echo sequences (GRASE), and segmented T1-weighted echo planar imaging (EPI) in comparison with conventional SE sequences in the detection of focal liver lesions. Method: Thirty-five patients with malignant focal liver lesions underwent MRI at 1.0 T. Results: All fast T2-weighted imaging techniques (FSE, UFSE, GRASE) showed fewer artifacts and overall better image quality than the conventional SE sequence. Quantitative analysis demonstrated that UFSE imaging had the highest tumor/liver contrast/noise ratio (C/N) (13.9 +/- 5.5) followed by FSE (12.7 +/- 4.5), T2 SE (10.9 +/- 4.2), and GRASE (10.0 +/- 4.8) sequences. The differences in C/N between the UFSE and T2 SE sequences was statistically significant (p < 0.05). C/N was significantly higher (p < 0.01) for the T1 SE (-7.4 +/- 3.8) than for the EPI sequence (-0.5 +/- 5.6). Conclusion: FSE sequences with shortened echo spacing are valuable for liver imaging at 1.0 T. In comparison with the T2 SE sequence, they yielded better image quality and comparable tumor/liver C/N.
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
BUTTS, K
;
RIEDERER, SJ
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
RIEDERER, SJ
;
EHMAN, RL
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
EHMAN, RL
;
FELMLEE, JP
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
FELMLEE, JP
;
GRIMM, RC
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
BUTTS, K
;
RIEDERER, SJ
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
RIEDERER, SJ
;
EHMAN, RL
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
EHMAN, RL
;
FELMLEE, JP
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
FELMLEE, JP
;
GRIMM, RC
论文数: 0引用数: 0
h-index: 0
机构:
MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905