Development of a high ratio isotope dilution mass spectrometry calibration technique for chemical metrology

被引:18
作者
Hearn, R [1 ]
Evans, P [1 ]
Sargent, M [1 ]
机构
[1] LGC, Teddington, Middx, England
关键词
D O I
10.1039/b504698j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
IDMS with calibration by "exact'' or "approximate signal matching'' methods offers a number of advantages for chemical metrology applications where measurements of low uncertainty are required for analytes at low concentrations in complex matrices. These methods have been applied extensively but are unsuitable for some important applications because in many cases, the concentration of the spike isotope in each measured blend of a sample or standard should be as close as possible to the concentration of the natural analyte isotope. In this paper we discuss recent work investigating the extent to which it is possible to move away from this ideal 1 : 1 blend isotope ratio whilst retaining the key benefits of the approximate matching technique. This has been used for the first time for applications where the sample has a very high analyte concentration, which would require unacceptably high amounts of spike with the existing method. The methodology has been validated for sulfur using a well-characterised candidate matrix reference material NIST SRM1624d. This is a diesel fuel sample that contains approximately 4000 mu g g(-1) sulfur. Results were obtained using a ratio for S-32/S-34 of 14, achieving accuracy and uncertainty comparable with the original method using a blend isotope ratio of 1.
引用
收藏
页码:1019 / 1023
页数:5
相关论文
共 23 条
[1]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[2]   Structured approach to achieving high accuracy measurements with isotope dilution inductively coupled plasma mass spectrometry [J].
Catterick, T ;
Fairman, B ;
Harrington, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1009-1013
[3]   MEASUREMENT PARAMETER SELECTION FOR QUANTITATIVE ISOTOPE-DILUTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
COLBY, BN ;
ROSECRANCE, AE ;
COLBY, ME .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1907-1911
[4]   Isotope-abundance variations of selected elements -: (IUPAC Technical Report) [J].
Coplen, TB ;
Böhlke, JK ;
De Bièvre, P ;
Ding, T ;
Holden, NE ;
Hopple, JA ;
Krouse, HR ;
Lamberty, A ;
Peiser, HS ;
Révész, K ;
Rieder, SE ;
Rosman, KJR ;
Roth, E ;
Taylor, PDP ;
Vocke, RD ;
Xiao, YK .
PURE AND APPLIED CHEMISTRY, 2002, 74 (10) :1987-2017
[5]   PRECISION MASS SPECTROMETRIC ISOTOPE DILUTION ANALYSIS [J].
DEBIEVRE, PJ ;
DEBUS, GH .
NUCLEAR INSTRUMENTS & METHODS, 1965, 32 (02) :224-&
[6]   Calibrated sulfur isotope abundance ratios of three IAEA sulfur isotope reference materials and V-CDT with a reassessment of the atomic weight of sulfur [J].
Ding, T ;
Valkiers, S ;
Kipphardt, H ;
De Bièvre, P ;
Taylor, PDP ;
Gonfiantini, R ;
Krouse, R .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2001, 65 (15) :2433-2437
[7]  
EURACHEM, 2000, QUANT UNC AN MEAS
[8]   High accuracy analysis of low level sulfur in diesel fuel by isotope dilution high resolution ICP-MS, using silicon for mass bias correction of natural isotope ratios [J].
Evans, P ;
Wolff-Briche, C ;
Fairman, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :964-969
[9]   A comparison of high accuracy isotope dilution techniques for the measurement of low level sulfur in gas oils [J].
Hearn, R ;
Berglund, M ;
Ostermann, M ;
Pusticek, N ;
Taylor, P .
ANALYTICA CHIMICA ACTA, 2005, 532 (01) :55-60
[10]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658