Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

被引:112
作者
Gutierrez-Chico, Juan Luis [1 ]
van Geuns, Robert Jan [1 ]
Regar, Evelyn [1 ]
van der Giessen, Willem J. [1 ]
Kelbaek, Henning [2 ]
Saunamaki, Kari [2 ]
Escaned, Javier [3 ]
Gonzalo, Nieves [3 ]
di Mario, Carlo [4 ]
Borgia, Francesco [4 ]
Nueesch, Eveline [5 ]
Garcia-Garcia, Hector M. [6 ]
Silber, Sigmund [7 ]
Windecker, Stephan [8 ]
Serruys, Patrick W. [1 ]
机构
[1] Thorax Ctr Rotterdam, Erasmus Med Ctr, NL-3015 CE Rotterdam, Netherlands
[2] Rigshosp, DK-2100 Copenhagen, Denmark
[3] Hosp Clin San Carlos, Madrid, Spain
[4] Royal Brompton Hosp, London SW3 6LY, England
[5] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
[6] Cardialysis BV, Rotterdam, Netherlands
[7] Kardiol Gemeinschaftspraxis & Praxisklin, Munich, Germany
[8] Inselspital Bern, Schweizer Herzzentrum, CH-3010 Bern, Switzerland
关键词
Tomography; optical coherence; Polymers; Poly(vinylidene fluoride-co-hexafluoropropylene); Zotarolimus; Everolimus; Drug-eluting stents; Coronary vessels; Angioplasty; transluminal; percutaneous coronary; BARE-METAL STENTS; POLYESTER ARTERIAL PROSTHESES; ACUTE MYOCARDIAL-INFARCTION; VESSEL WALL RESPONSE; STRUT COVERAGE; INTRAVASCULAR ULTRASOUND; CORONARY-ARTERIES; VASCULAR-RESPONSE; DURABLE POLYMER; SHEAR-STRESS;
D O I
10.1093/eurheartj/ehr182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymercoated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and throm-bogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P = 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P = 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 +/- 99 mu m in ZES and 142 +/- 113 mu m in EES (P = 0.466). No differences in per cent neointimal volume obstruction (12.5 +/- 7.9 vs. 15.0 +/- 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.
引用
收藏
页码:2454 / 2463
页数:10
相关论文
共 41 条
[1]   An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[2]  
Carter AJ, 2006, TRANSC CARD THER ANN
[3]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[4]  
Duckers Henricus J, 2007, EuroIntervention, V3, P67
[5]  
Duckers Henricus J, 2007, EuroIntervention, V3, P350
[6]   Pathological analysis of local delivery of paclitaxel via a polymer-coated stent [J].
Farb, A ;
Heller, PF ;
Shroff, S ;
Cheng, L ;
Kolodgie, FD ;
Carter, AJ ;
Scott, DS ;
Froehlich, J ;
Virmani, R .
CIRCULATION, 2001, 104 (04) :473-479
[7]   Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[8]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[9]   Coronary Stents Current Status [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S1-S42
[10]   Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries [J].
Gijsen, FJH ;
Oortman, RM ;
Wentzel, JJ ;
Schuurbiers, JCH ;
Tanabe, K ;
Degertekin, M ;
Ligthart, JM ;
Thury, A ;
de Feyter, PJ ;
Serruys, PW ;
Slager, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1325-1328