A low blood volume LC-MS/MS assay for the quantification of fentanyl and its major metabolites norfentanyl and despropionyl fentanyl in children

被引:37
作者
Clavijo, Claudia F. [1 ]
Thomas, James Joseph [1 ]
Cromie, Meghan [1 ]
Schniedewind, Bjoern [1 ]
Hoffman, Keith L. [1 ]
Christians, Uwe [1 ]
Galinkin, Jeffrey L. [1 ,2 ]
机构
[1] Univ Colorado Denver, Dept Anesthesiol, Aurora, CO 80045 USA
[2] Childrens Hosp Colorado, Aurora, CO USA
基金
美国国家卫生研究院;
关键词
Despropionyl fentanyl; Dried blood spots; Fentanyl; Human plasma; Norfentanyl; CHROMATOGRAPHY-MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; HUMAN PLASMA; ULTRAVIOLET DETECTION; SCREENING METHOD; SUFENTANIL; ALFENTANIL; INFANTS;
D O I
10.1002/jssc.201100422
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preterm and term neonates often require surgical procedures and analgesia. However, our knowledge about neonatal pharmacokinetics of fentanyl, the most commonly used drug for these procedures, and its metabolites is still incomplete. To facilitate pharmacokinetic studies of fentanyl and its metabolites in neonates and other children, we developed and validated an LC-MS/MS method based on minimally invasive, low blood volume sampling. LC-MS/MS was used for the simultaneous analysis of fentanyl, despropionyl fentanyl (DPF), and norfentanyl from dried blood samples (DBS) collected on filter paper. Positive ions were monitored using multiple reaction monitoring. Since the standard matrix for measuring fentanyl blood concentrations is plasma, the assay was developed and validated in plasma, whole blood, and then DBS. Our method was able to measure clinically relevant levels of fentanyl and its metabolites. In DBS, the lower limits of quantification were 100?pg/mL for fentanyl with a range of reliable response from 0.1 to 100?ng/mL (r2>0.99) and 250?pg/mL for both DPF and norfentanyl with a range of reliable response from 0.25 to 100?ng/mL (r2>0.99). In plasma and in DBS inter-day accuracy and precisions of fentanyl met predefined acceptance criteria and also indicated comparable assay performance in both matrices.
引用
收藏
页码:3568 / 3577
页数:10
相关论文
共 35 条
[1]   Determination of ropivacaine and its metabolites in patient urine: Advantage of liquid chromatography-tandem mass spectrometry over liquid chromatography-UV detection and liquid chromatography-mass spectrometry [J].
Abdel-Rehim, M ;
Bielenstein, M ;
Askemark, Y .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :253-260
[2]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation
[3]  
[Anonymous], 2004, EVALUATION PRECISION
[4]   Determination of fentanyl in human plasma by head-space solid-phase microextraction and gas chromatography-mass spectrometry [J].
Bagheri, Habib ;
Es-haghi, Ali ;
Khalilian, Faezeh ;
Rouini, Mohammad-Reza .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1763-1768
[5]   Determination of remifentanil in human blood by capillary gas chromatography with nitrogen-selective detection [J].
Bjorksten, AR ;
Chan, C ;
Crankshaw, DP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (01) :97-101
[6]   Quantitative analysis of fentanyl in rat plasma by gas chromatography with nitrogen-phosphorus detection [J].
Choi, HS ;
Shin, HC ;
Khang, G ;
Rhee, JM ;
Lee, HB .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 765 (01) :63-69
[7]   A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry [J].
Clavijo, Claudia F. ;
Hoffman, Keith L. ;
Thomas, James J. ;
Carvalho, Brendan ;
Chu, Larry F. ;
Drover, David R. ;
Hammer, Gregory B. ;
Christians, Uwe ;
Galinkin, Jeffrey L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (03) :715-728
[8]   LC-MS/MS analysis of fentanyl and norfentanyl in a fatality due to application of multiple Durogesic® transdermal therapeutic systems [J].
Coopman, Vera ;
Cordonnier, Jan ;
Pien, Karen ;
Van Varenbergh, Dirk .
FORENSIC SCIENCE INTERNATIONAL, 2007, 169 (2-3) :223-227
[9]   Employment of 4-(1-imidazolyl)phenol as a luminol signal enhancer in a competitive-type chemiluminescence immunoassay and its comparison with the conventional antigen-horseradish peroxidase conjugate-based assay [J].
Dotsikas, Y ;
Loukas, YL .
ANALYTICA CHIMICA ACTA, 2004, 509 (01) :103-109
[10]   Determination of umbilical cord and maternal plasma concentrations of fentanyl by using novel spectrophotometric and chemiluminescence enzyme immunoassays [J].
Dotsikas, Y ;
Loukas, YL ;
Siafaka, I .
ANALYTICA CHIMICA ACTA, 2002, 459 (02) :177-185