Brucella detection in blood:: comparison of the BacT/Alert standard aerobic bottle, BacT/Alert FAN aerobic bottle and BacT/Alert enhanced FAN aerobic bottle in simulated blood culture

被引:11
作者
Sümerkan, B [1 ]
Gökahmetoglu, S [1 ]
Esel, D [1 ]
机构
[1] Erciyes Univ, Dept Clin Microbiol, Kayseri, Turkey
关键词
Brucella; BacT/Alert blood culture system;
D O I
10.1046/j.1198-743x.2001.00275.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The objective of this study was to compare the performances of the standard aerobic bottle (StAe), FAN aerobic (FANAe) and enhanced FAN aerobic (E-FANAe) (the charcoal component of the FANAe was revised recently to improve the feasibility of Gram smear interpretation) blood culture bottles for BacT/Alert system for the detection of Brucella melitensis in simulated blood culture. Triplicate strains of eight clinical isolates of B. melitensis were studied. Each bottle was inoculated with 5 mL of freshly collected human blood at three different targeted bacterial inocula (10(1), 10(2) and 10(3) CFU/bottle). All bottles were monitored for up to 21 days or until they became positive. The results of time to detection (TTD) on the eight B. melitensis samples were as follows: at 10(1) CFU/bottle, the E-FANAe had a mean TTD significantly shorter than the StAe (48 h vs. 56.2 h, P < 0.05); and at 10(3) CFU/bottle, the FANAe and E-FANAe had a mean TTD significantly shorter than the StAe (41.2 h and 40 h vs. 45.6 h, P < 0.05). The reproducibilities (no.of positive signals/no.of all bottles) of three bottle systems were as follows: at 10(1) CFU/bottle, the reproducibilities of StAe, FANAe and E-FANAe were 96, 83 and 58%, respectively. At 10(3) CFU/bottle, the reproducibilities of StAe, FANAe and E-FANAe were 95, 95 and 91%, respectively. Positive results for the presence of bacteria in Gram smears were confirmed in 68% of StAe, 54% of FANAe and 90% of E-FANAe. In case of suspected brucellosis, the combination of one StAe bottle and one E-FANAe bottle seems to provide the highest and fastest recovery of the organism.
引用
收藏
页码:369 / 372
页数:4
相关论文
共 14 条
[1]   Rapid diagnosis of Brucella bacteremia by using the BACTEC 9240 system [J].
Bannatyne, RM ;
Jackson, MC ;
Memish, Z .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) :2673-2674
[2]  
DUNNE WM, 1997, BLOOD CULTURES, V3
[3]   FACTORS AFFECTING DETECTION OF BRUCELLA-MELITENSIS BY BACTEC NR730, A NONRADIOMETRIC SYSTEM FOR HEMOCULTURES [J].
GAMAZO, C ;
VITAS, AI ;
LOPEZGONI, I ;
DIAZ, R ;
MORIYON, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (12) :3200-3203
[4]   NEISSERIA-GONORRHOEAE CELL-ENVELOPE - PERMEABILITY TO HYDROPHOBIC MOLECULES [J].
LYSKO, PG ;
MORSE, SA .
JOURNAL OF BACTERIOLOGY, 1981, 145 (02) :946-952
[5]  
MAYER NP, 1995, MANUAL CLIN MICROBIO, P549
[6]   FASTER ISOLATION OF BRUCELLA SPP FROM BLOOD BY ISOLATOR COMPARED WITH BACTEC NR [J].
NAVAS, E ;
GUERRERO, A ;
COBO, J ;
LOZA, E .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1993, 16 (01) :79-81
[7]  
Rohner Peter, 1999, Clin Microbiol Infect, V5, P513, DOI 10.1111/j.1469-0691.1999.tb00429.x
[8]  
Ruiz Castaneda M., 1961, Bulletin of the World Health Organization, V24, P73
[9]   Diagnosis of brucellosis by using blood cultures [J].
Ruiz, J ;
Lorente, I ;
Perez, J ;
Simarro, E ;
MartinezCampos, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (09) :2417-2418
[10]   RAPID DIAGNOSIS OF BRUCELLA-MELITENSIS IN BLOOD - SOME OPERATIONAL CHARACTERISTICS OF THE BACT/ALERT [J].
SOLOMON, HM ;
JACKSON, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (01) :222-224