Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry

被引:104
作者
Dirtu, Alin C. [1 ,2 ]
Roosens, Laurence [1 ]
Geens, Tinne [1 ]
Gheorghe, Adriana [1 ,3 ]
Neels, Hugo [1 ]
Covaci, Adrian [1 ]
机构
[1] Univ Antwerp, Toxicol Ctr, Dept Pharmaceut Sci, B-2610 Antwerp, Belgium
[2] Al I Cuza Univ Iassy, Dept Inorgan & Analyt Chem, Iasi 700506, Romania
[3] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest 050663, Romania
关键词
bisphenol A; triclosan; tetrabromobisphenol A; solid-phase extraction; gas chromatography-mass spectrometry; human serum;
D O I
10.1007/s00216-007-1807-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70 degrees C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K(2)CO(3) 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL(-1), 0.09 ng mL(-1) and 0.05 ng mL(-1), respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL(-1)) and TCS (0.52 ng mL(-1)) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL(-1)) were found in Belgium samples compared to Norwegian serum.
引用
收藏
页码:1175 / 1181
页数:7
相关论文
共 36 条
[1]   Triclosan, a commonly used bactericide found in human milk and in the aquatic environment in Sweden [J].
Adolfsson-Erici, M ;
Pettersson, M ;
Parkkonen, J ;
Sturve, J .
CHEMOSPHERE, 2002, 46 (9-10) :1485-1489
[2]   Determination of triclosan as its pentafluorobenzoyl ester in human plasma and milk using electron capture negative ionization mass spectrometry [J].
Allmyr, Mats ;
McLachlan, Michael S. ;
Sandborgh-Englund, Gunilla ;
Adolfsson-Erici, Margaretha .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6542-6546
[3]   Triclosan in plasma and milk from Swedish nursing mothers and their exposure via personal care products [J].
Allmyr, Mats ;
Adolfsson-Erici, Margaretha ;
McLachlan, Michael S. ;
Sandborgh-Englund, Gunilla .
SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 372 (01) :87-93
[4]   Triclosan: Applications and safety [J].
Bhargava, HN ;
Leonard, PA .
AMERICAN JOURNAL OF INFECTION CONTROL, 1996, 24 (03) :209-218
[5]   Solid-phase extraction/high-performance liquid chromatography-electrospray mass spectrometry to determine endocrine disruptors in water samples [J].
Brossa, L ;
Pocurull, E ;
Borrull, F ;
Marcé, RM .
CHROMATOGRAPHIA, 2004, 59 (7-8) :419-423
[6]   New multiresidue analytical method dedicated to trace level measurement of brominated flame retardants in human biological matrices [J].
Cariou, R ;
Antignac, JP ;
Marchand, P ;
Berrebi, A ;
Zalko, D ;
Andre, F ;
Le Bizec, B .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (02) :144-152
[7]   Simultaneous determination of the endocrine disrupting compounds nonylphenol, nonylphenol ethoxylates, triclosan and bisphenol A in wastewater and sewage sludge by gas chromatography-mass spectrometry [J].
Gatidou, Georgia ;
Thomaidis, Nikolaos S. ;
Stasinakis, Athanasios S. ;
Lekkas, Themistokles D. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) :32-41
[8]   Mass balance assessment of triclosan removal during conventional sewage treatment [J].
Heidler, Jochen ;
Halden, Rolf U. .
CHEMOSPHERE, 2007, 66 (02) :362-369
[9]   Development of stable isotope dilution quantification liquid chromatography-mass spectrometry method for estimation of exposure levels of bisphenol A, 4-tert-octylphenol, 4-nonylphenol, tetrabromobisphenol A, and pentachlorophenol in indoor air [J].
Inoue, K. ;
Yoshida, S. ;
Nakayama, S. ;
Ito, R. ;
Okanouchi, N. ;
Nakazawa, H. .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2006, 51 (04) :503-508
[10]   Exposure to polybrominated diphenyl ethers and tetrabromobisphenol A among computer technicians [J].
Jakobsson, K ;
Thuresson, K ;
Rylander, L ;
Sjödin, A ;
Hagmar, L ;
Bergman, Å .
CHEMOSPHERE, 2002, 46 (05) :709-716