Theoretical Design and Analysis of Multivolume Digital Assays with Wide Dynamic Range Validated Experimentally with Microfluidic Digital PCR

被引:119
作者
Kreutz, Jason E. [1 ,2 ]
Munson, Todd [3 ,4 ]
Huynh, Toan [1 ,2 ]
Shen, Feng [1 ,2 ]
Du, Wenbin [1 ,2 ]
Ismagilov, Rustem F. [1 ,2 ]
机构
[1] Univ Chicago, Dept Chem, Chicago, IL 60637 USA
[2] Univ Chicago, Inst Biophys Dynam, Chicago, IL 60637 USA
[3] Argonne Natl Lab, Argonne, IL 60439 USA
[4] Univ Chicago, Computat Inst, Chicago, IL 60637 USA
关键词
PROBABLE-NUMBER-PCR; TIME RT-PCR; VIRAL LOAD; DETECTION LIMITS; AMPLIFICATION; QUANTIFICATION; DNA; ENUMERATION; DROPLETS; DISEASE;
D O I
10.1021/ac201658s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a protocol using theoretical methods and free software to design and analyze multivolume digital PCR (MV digital PCR) devices; the theory and software are also applicable to design and analysis of dilution series in digital PCR MV digital PCR minimizes the total number of wells required for "digital" (single (single molecule) measurements while maintaining high dynamic range and high resolution. In some examples, multivolume designs with fewer than 200 total wells are predicted to provide dynamic range with 5-fold resolution similar to that of single-volume designs requiring 12 000 wells. Mathematical techniques were utilized and expanded to maximize the information obtained from each experiment and to quantify performance of devices and were experimentally validated using the SlipChip platform. MV digital PCR was demonstrated to perform reliably, and results from wells of different volumes agreed with one another. No artifacts due to different surface-to-volume ratios were observed, and single molecule amplification in volumes ranging from 1 to 125 nL was self-consistent. The device presented here was designed to meet the testing requirements for measuring clinically relevant levels of HIV viral load at the point-of-care (in plasma, <500 molecules/mL to >1000 000 molecules/mL), and the predicted resolution and dynamic range was experimentally validated using a control sequence of DNA. This approach simplifies digital PCR experiments, saves space, and thus enables multiplexing using separate areas for each sample on one chip, and facilitates the development of new high-performance diagnostic tools for resource-limited applications. The theory and software presented here are general and are applicable to designing and analyzing other digital analytical platforms including digital immunoassays and digital bacterial analysis. It is not limited to SlipChip and could also be useful for the design of systems on platforms including valve-based and droplet-based platforms. In a separate publication by Shen et al. (J. Am. Chem. Soc., 2011, DOI: 10.1021/ja2060116), this approach is used to design and test digital RT-PCR devices for quantifying RNA.
引用
收藏
页码:8158 / 8168
页数:11
相关论文
共 70 条
  • [1] Approximate is better than "exact" for interval estimation of binomial proportions
    Agresti, A
    Coull, BA
    [J]. AMERICAN STATISTICIAN, 1998, 52 (02) : 119 - 126
  • [2] Applied Biosystems Life Technologies, 2010, DIG PCR US OPENARRAY
  • [3] Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number
    Bhat, Somanath
    Herrmann, Jan
    Armishaw, Paul
    Corbisier, Philippe
    Emslie, Kerry R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) : 457 - 467
  • [4] Digital MDA for enumeration of total nucleic acid contamination
    Blainey, Paul C.
    Quake, Stephen R.
    [J]. NUCLEIC ACIDS RESEARCH, 2011, 39 (04) : e19
  • [5] Detecting bacteria and determining their susceptibility to antibiotics by stochastic confinement in nanoliter droplets using plug-based microfluidics
    Boedicker, James Q.
    Li, Liang
    Kline, Timothy R.
    Ismagilov, Rustem F.
    [J]. LAB ON A CHIP, 2008, 8 (08) : 1265 - 1272
  • [6] The contribution of assay variation and biological variation to the total variability of plasma HIV-1 RNA measurements
    Brambilla, D
    Reichelderfer, PS
    Bremer, JW
    Shapiro, DE
    Hershow, RC
    Katzenstein, DA
    Hammer, SM
    Jackson, B
    Collier, AC
    Sperling, RS
    Fowler, MG
    Coombs, RW
    [J]. AIDS, 1999, 13 (16) : 2269 - 2279
  • [7] The applicability of digital PCR for the assessment of detection limits in GMO analysis
    Burns, M. J.
    Burrell, A. M.
    Foy, C. A.
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2010, 231 (03) : 353 - 362
  • [8] Quantitative real-time RT-PCR - a perspective
    Bustin, SA
    Benes, V
    Nolan, T
    Pfaffl, MW
    [J]. JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2005, 34 (03) : 597 - 601
  • [9] HIV viral load monitoring in resource-limited regions: Optional or necessary?
    Calmy, Alexandra
    Ford, Nathan
    Hirschel, Bernard
    Reynolds, Steven J.
    Lynen, Lut
    Goemaere, Eric
    de la Vega, Felipe Garcia
    Perrin, Luc
    Rodriguez, William
    [J]. CLINICAL INFECTIOUS DISEASES, 2007, 44 (01) : 128 - 134
  • [10] Comparison of most probable number-PCR and most probable number-foci detection method for quantifying infectious Cryptosporidium parvum oocysts in environmental samples
    Carey, Christine M.
    Lee, Hung
    Trevors, Jack T.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 67 (02) : 363 - 372