New basis for the Australian realization of the candela

被引:6
作者
Gardner, JL [1 ]
Butler, DJ [1 ]
Atkinson, EG [1 ]
Wilkinson, FJ [1 ]
机构
[1] CSIRO, Natl Measurement Lab, Lindfield, NSW 2070, Australia
关键词
D O I
10.1088/0026-1394/35/4/3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Photometric units in Australia are currently derived from power measurements made with a room-temperature electrical-substitution radiometer. This basis has been transferred to a cryogenic radiometer. The cryogenic radiometer was used to calibrate the absolute responsivity of a four-element, planar, transmission trap detector (measuring the transmission loss each usage), at laser wavelengths. Modelling of the quantum defect then provided a reference for absolute spectral responsivity throughout the photometric wavelength range. This was used to measure the responsivity of a number of photometers at the mercury green line and to calculate correction factors for CIE Illuminant A. The candela so derived essentially agrees with our existing unit, maintained on a set of lamps. The trap detector was also used to determine the polarization properties of the monochromator.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 14 条
[1]   6TH COMPARISON OF NATIONAL STANDARDS OF LUMINOUS INTENSITY AND OF LUMINOUS FLUX (1985) [J].
BONHOURE, J .
METROLOGIA, 1987, 24 (04) :157-162
[2]   RADIOMETRIC REALIZATION OF PHOTOMETRIC UNITS [J].
BROWN, WJ .
METROLOGIA, 1975, 11 (03) :111-115
[3]   Diffraction effects in the radiometry of coherent beams [J].
Butler, DJ ;
Kohler, R ;
Forbes, GW .
APPLIED OPTICS, 1996, 35 (13) :2162-2166
[4]   Realization of the candela from a partial filtering V (lambda) detector traceable to a cryogenic radiometer [J].
Campos, J ;
Corrons, A ;
Pons, A ;
Corredera, P .
METROLOGIA, 1996, 32 (06) :675-679
[5]   The NIST detector-based luminous intensity scale [J].
Cromer, CL ;
Eppeldauer, G ;
Hardis, JE ;
Larason, TC ;
Ohno, Y ;
Parr, AC .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (02) :109-132
[6]   TRANSMISSION TRAP DETECTORS [J].
GARDNER, JL .
APPLIED OPTICS, 1994, 33 (25) :5914-5918
[7]   A four-element transmission trap detector [J].
Gardner, JL .
METROLOGIA, 1996, 32 (06) :469-472
[8]  
GARDNER JL, 1988, I PHYS C SER, V92, P63
[9]   Realization of a scale of absolute spectral response using the national institute of standards and technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Cromer, CL .
APPLIED OPTICS, 1996, 35 (22) :4392-4403
[10]  
GIACOMO P, 1980, METROLOGIA, V16, P55