The effects of the electrode system geometry on the properties of contactless conductivity detectors for capillary electrophoresis

被引:32
作者
Novotny, M [1 ]
Opekar, FE [1 ]
Stulik, K [1 ]
机构
[1] Charles Univ, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, Prague 12840 2, Czech Republic
关键词
capillary electrophoresis; contactless conductometric detector; electrode geometry;
D O I
10.1002/elan.200403232
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The basic analytical parameters of contactless conductivity detectors with planar, semi-tubular and tubular electrodes have been compared. It has been found that the differences in the analytical parameters of the detectors are not significant for analytical use. The mean values of baseline peak-to-peak noise of 0.27, 0.35 and 0.33 mV, sensitivities of 0.97, 2.08 and 2.27 mV/pg (for K+ ion), limits of detection of 0.93, 0.65 and 0.53, and the heights equivalent to a theoretical plate of 2.83, 2.39 and 2.40 mu m were obtained for the detectors with planar, semi/tubular and tubular electrodes, respectively. Modifications of the basic detectors, namely a detector with thinned capillary wall and planar electrodes, and a detector with semi-tubular electrodes placed one against the other on the opposite sides of the capillary were also tested. ne configuration with the electrodes placed one against the other permits detector construction with zero gap between the electrodes without increasing the noise; when the electrodes overlap, the detector begins to operate as a permittivity detector.
引用
收藏
页码:1181 / 1186
页数:6
相关论文
共 25 条
[1]  
Baltussen E, 2002, ELECTROPHORESIS, V23, P2888, DOI 10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO
[2]  
2-4
[3]   Dual photometric-contactless conductometric detector for capillary electrophoresis [J].
Chvojka, T ;
Jelínek, I ;
Opekar, F ;
Stulík, K .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :13-21
[4]  
da Silva JAF, 2002, J CHROMATOGR A, V942, P249
[5]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[6]  
GABRIELLI C, 1995, ELECTROCHEMICAL IMPE, P246
[7]  
Gas B, 2002, ELECTROPHORESIS, V23, P3520, DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO
[8]  
2-G
[9]   Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry [J].
Kuban, P ;
Hauser, PC .
ELECTROPHORESIS, 2004, 25 (20) :3387-3397
[10]   Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part II: Signal-to-noise ratio and stray capacitance [J].
Kuban, P ;
Hauser, PC .
ELECTROPHORESIS, 2004, 25 (20) :3398-3405