Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method

被引:67
作者
Christian, Timothy F. [1 ]
Aletras, Anthony H. [2 ]
Arai, Andrew E. [2 ]
机构
[1] Univ Vermont, Coll Med, Dept Med, Burlington, VT 05495 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
MRI perfusion; hyperemia; adenosine; myocardial blood flow; imaging;
D O I
10.1002/jmri.21383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the dual-bolus to single-bolus quantitative first-pass magnetic resonance myocardial perfusion imaging for estimation of absolute myocardial blood flow (MBF). Materials and Methods: Dogs had local hyperemia. of MBF in the left anterior descending (LAD) coronary artery (intra-coronary adenosine). Animals (n = 6) had sequential single-and dual-bolus perfusion studies with microsphere determination of absolute MBF. Perfusion imaging was performed using a saturation-recovery gradient-echo sequence. Absolute MBF was by Fermi function deconvolution and compared to transmural, endocardial, and epicardial microsphere values in the same region of interest (ROT). Results: Signal and contrast were significantly higher for the dual-bolus perfusion images. The correlation with MBF by microspheres was r = 0.94 for the dual-bolus method and r = 0.91 for the single-bolus method. There was no significant difference between MRI and microsphere MBF values for control or hyperemic zones for transmural segments for either technique. When the ROT was reduced to define endocardial and epicardial zones, single-bolus MR first-pass imaging significantly overestimated MBF and had a significantly larger absolute error vs. microspheres when compared to dual-bolus perfusion. Conclusion: Both single-bolus and dual-bolus perfusion methods correlate closely with MBF but the signal and contrast of the dual-bolus images are greater. With smaller nontransmural ROIs where signal is reduced, the dual-bolus method appeared to provide slightly more accurate results.
引用
收藏
页码:1271 / 1277
页数:7
相关论文
共 23 条
[1]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[2]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[3]   Anatomy of an emerging diagnostic test - Computed tomographic coronary angiography [J].
Christian, TF .
CIRCULATION, 2005, 112 (15) :2222-2225
[4]   REGIONAL TRANSIT-TIME ESTIMATION FROM IMAGE RESIDUE CURVES [J].
CLOUGH, AV ;
ALTINAWI, A ;
LINEHAN, JH ;
DAWSON, CA .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (02) :128-143
[5]   Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI [J].
Ding, SJ ;
Wolff, SD ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :514-519
[6]   TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS [J].
DOMENECH, RJ ;
HOFFMAN, JIE ;
NOBLE, MIM ;
SAUNDERS, KB ;
HENSON, JR ;
SUBIJANTO, S .
CIRCULATION RESEARCH, 1969, 25 (05) :581-+
[7]   Multislice first-pass cardiac perfusion MRI: Validation in a model of myocardial infarction [J].
Epstein, FH ;
London, JF ;
Peters, DC ;
Goncalves, LM ;
Agyeman, K ;
Taylor, J ;
Balaban, RS ;
Arai, AE .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :482-491
[8]   Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance [J].
Gatehouse, PD ;
Elkington, AG ;
Ablitt, NA ;
Yang, GZ ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :39-45
[9]   MR IMAGING USING STIMULATED ECHOES (STEAM) [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
BOMSDORF, H ;
KUNZ, D ;
TISCHLER, R .
RADIOLOGY, 1986, 160 (03) :787-790
[10]   Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans [J].
Hsu, LY ;
Rhoads, KL ;
Holly, JE ;
Kellman, P ;
Aletras, AH ;
Arai, AE .