Application of cysteine monolayers for electrochemical determination of sub-ppb copper(II)

被引:178
作者
Liu, AC [1 ]
Chen, DC [1 ]
Lin, CC [1 ]
Chou, HH [1 ]
Chen, CH [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1021/ac980956g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrodes with the functionality of amino acids can be easily prepared by taking advantage of strong sulfur-gold interactions and immersing gold electrodes into cysteine solutions. Such electrodes exhibit excellent sensitivity and selectivity toward copper(II) determination, because the bidentate chelation of amino acids toward copper(II) is effective and far superior than that toward any other metal ions. In this study, we demonstrate that at a preconcentration time of 5 min the cysteine-modified electrode has a dynamic range of 2 orders of magnitude (from 5.0 to 0.050 mu g/L) and the detection limit is as low as 25 ng/L (0.39 nM). This method is applied to the determination of copper(II) in two reference materials, SLEW-2 (river water, 1.62 mu g/L) and CASS-3 (seawater, 0.517 mu g/L). The results agree satisfactorily with the certified values.
引用
收藏
页码:1549 / 1552
页数:4
相关论文
共 36 条
[21]   ION-SELECTIVE MONOLAYER MEMBRANES BASED UPON SELF-ASSEMBLING TETRADENTATE LIGAND MONOLAYERS ON GOLD ELECTRODES .3. APPLICATION AS SELECTIVE ION SENSORS [J].
STEINBERG, S ;
RUBINSTEIN, I .
LANGMUIR, 1992, 8 (04) :1183-1187
[22]   Metal ion trace detection by a chelator-modified gold electrode: A comparison of surface to bulk affinity [J].
Stora, T ;
Hovius, R ;
Dienes, Z ;
Pachoud, M ;
Vogel, H .
LANGMUIR, 1997, 13 (20) :5211-5214
[23]   Fiber optic biosensor for Co(II) and Cu(II) based on fluorescence energy transfer with an enzyme transducer [J].
Thompson, RB ;
Ge, ZF ;
Patchan, M ;
Huang, CC ;
Fierke, CA .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (6-7) :557-564
[24]   Exploiting polypeptide motifs for the design of selective Cu(II) ion chemosensors [J].
Torrado, A ;
Walkup, GK ;
Imperiali, B .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (03) :609-610
[25]   DISSOLUTION OF COLD ELECTRODES IN ALKALINE MEDIA CONTAINING CYSTEINE [J].
TUDOS, AJ ;
JOHNSON, DC .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :557-560
[26]   Selective determination of Cr(VI) by a self-assembled monolayer-based electrode [J].
Turyan, I ;
Mandler, D .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :894-897
[27]   SELF-ASSEMBLED MONOLAYERS IN ELECTROANALYTICAL CHEMISTRY - APPLICATION OF OMEGA-MERCAPTOCARBOXYLIC ACID MONOLAYERS FOR ELECTROCHEMICAL DETERMINATION OF ULTRALOW LEVELS OF CADMIUM(II) [J].
TURYAN, I ;
MANDLER, D .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :58-63
[28]   Formation and structure of self-assembled monolayers [J].
Ulman, A .
CHEMICAL REVIEWS, 1996, 96 (04) :1533-1554
[29]  
Ulman A., 1991, INTRO ULTRATHIN ORGA
[30]   L-CYSTEINE ADSORBED ON GOLD AND COPPER - AN X-RAY PHOTOELECTRON-SPECTROSCOPY STUDY [J].
UVDAL, K ;
BODO, P ;
LIEDBERG, B .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1992, 149 (01) :162-173