mfERG waveform characteristics in the RS1h mouse model featuring a 'negative' ERG

被引:7
作者
Seeliger, MW
Weber, BHF
Besch, D
Zrenner, E
Schrewe, H
Mayser, H
机构
[1] Univ Tubingen, Hosp Eye, Retinal Electodiagnost Res Grp, Dept 2, D-72076 Tubingen, Germany
[2] Univ Wurzburg, Bioctr, Inst Human Genet, Wurzburg, Germany
[3] Univ Birmingham, Sch Biosci, Edgbaston, England
关键词
animal model; electrophysiology; multifocal ERG; X-linked juvenile retinoschisis;
D O I
10.1023/A:1024496130538
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Several retinal disorders lead to a relatively greater attenuation of the b-wave compared to the a-wave of the electroretinogram (ERG), a constellation called 'negative' ERG. To determine the waveform characteristics of multifocal ERGs (mfERGs) and their dependence on recording parameters in such a case, we studied the Rs1h(-/Y) mouse, the model for x-linked juvenile retinoschisis. mfERGs were recorded with a VERIS 4 system connected to a piggyback stimulator prototype that added the stimulus to the optical pathway of a HRA scanning-laser ophthalmoscope (SLO) by means of a wavelength-sensitive mirror. Real-time fundus visualization was achieved with the infrared laser of the SLO (835 nm). High-pass filter settings and the time interval used by the 'artefact removal' feature were varied to study their influence on the waveform. The mfERG in the Rs1h(-/Y) mouse had a 'negative' shape. However, the high-pass filter setting had to be lowered from the usual 10 Hz down to about 2 Hz in order to obtain that result, otherwise the negative shape was lost and mainly a positive peak remained. Similarly, a short time interval used by the 'artefact removal' feature also removed the negative shape. The Rs1h(-/Y) mouse was found to be a valuable model of diseases with a 'negative' waveform shape also in mfERG. Our results underline the importance of a lower high-pass filter cutoff frequency when recording mfERGs in such disorders. In addition, if the 'artefact removal' feature is used, it should be verified that it doesn't distort the waveform shape.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 18 条
[1]  
BESCH D, 1998, 36 ISCEV S HRAD KRAL, P13
[2]   A comparison of the components of the multifocal and full-field ERGs [J].
Hood, DC ;
Seiple, W ;
Holopigian, K ;
Greenstein, V .
VISUAL NEUROSCIENCE, 1997, 14 (03) :533-544
[3]   Assessing retinal function with the multifocal technique [J].
Hood, DC .
PROGRESS IN RETINAL AND EYE RESEARCH, 2000, 19 (05) :607-646
[4]   Evidence for a ganglion cell contribution to the primate electroretinogram (ERG): Effects of TTX on the multifocal ERG in macaque [J].
Hood, DC ;
Frishman, LJ ;
Viswanathan, S ;
Robson, JG ;
Ahmed, J .
VISUAL NEUROSCIENCE, 1999, 16 (03) :411-416
[5]   Assessment of local retinal function in patients with retinitis pigmentosa using the multi-focal ERG technique [J].
Hood, DC ;
Holopigian, K ;
Greenstein, V ;
Seiple, W ;
Li, J ;
Sutter, EE ;
Carr, RE .
VISION RESEARCH, 1998, 38 (01) :163-179
[6]   Technical aspects of multifocal ERG recording [J].
David Keating ;
Stuart Parks ;
Aled Evans .
Documenta Ophthalmologica, 2000, 100 (2-3) :77-98
[7]  
Keating David, 1996, Documenta Ophthalmologica, V92, P291, DOI 10.1007/BF02584083
[8]  
Kondo M, 2001, INVEST OPHTH VIS SCI, V42, P1342
[9]   Spatial cone activity distribution in diseases of the posterior pole determined by multifocal electroretinography [J].
Kretschmann, U ;
Seeliger, M ;
Ruether, K ;
Usui, T ;
Zrenner, E .
VISION RESEARCH, 1998, 38 (23) :3817-3828
[10]   Multifocal electroretinography in patients with Stargardt's macular dystrophy [J].
Kretschmann, U ;
Seeliger, MW ;
Ruether, K ;
Usui, T ;
Apfelstedt-Sylla, E ;
Zrenner, E .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (03) :267-275