Comparison of real-time instruments used to monitor airborne particulate matter

被引:198
作者
Chung, A
Chang, DPY
Kleeman, MJ
Perry, KD
Cahill, TA
Dutcher, D
McDougall, EM
Stroud, K
机构
[1] Univ Calif Davis, Dept Civil & Environm Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, DELTA Air Qual Grp, Davis, CA USA
[3] Rupprecht & Pataschnick Inc, Albany, NY USA
[4] Calif Air Resources Board, Special Purpose Monitoring & Data Support Sect, Sacramento, CA USA
关键词
D O I
10.1080/10473289.2001.10464254
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurements collected using five real-time continuous airborne particle monitors were compared to measurements made using reference filter-based samplers at Bakersfield, CA, between December 2, 1998, and January 31, 1999. The purpose of this analysis was to evaluate the suitability of each instrument for use in a real-time continuous monitoring network designed to measure the mass of airborne particles with an aerodynamic diam less than 2.5 mum (PM2.5) under wintertime conditions in the southern San Joaquin Valley. Measurements of airborne particulate mass made with a beta attenuation monitor (BAM), an integrating nephelometer, and a continuous aerosol mass monitor (CAMM) were found to correlate well with reference measurements made with a filter-based sampler. A Dusttrak aerosol sampler overestimated airborne particle concentrations by a factor of similar to3 throughout the study. Measurements of airborne particulate matter made with a tapered element oscillating microbalance (TEOM) were found to be lower than the reference filter-based measurements by an amount approximately equal to the concentration of NH4NO3 observed to be present in the airborne particles. The performance of the Dusttrak sampler and the integrating nephelometer was affected by the size distribution of airborne particulate matter. The performance of the BAM, the integrating nephelometer, the CAMM, the Dusttrak sampler, and the TEOM was not strongly affected by temperature, relative humidity, wind speed, or wind direction within the range of conditions encountered in the current study. Based on instrument performance, the BAM, the integrating nephelometer, and the CAMM appear to be suitable candidates for deployment in a real-time continuous PM2.5 monitoring network in central California for the range of winter conditions and aerosol composition encountered during the study.
引用
收藏
页码:109 / 120
页数:12
相关论文
共 23 条
[1]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[2]  
Anderson TL, 1996, J ATMOS OCEAN TECH, V13, P967, DOI 10.1175/1520-0426(1996)013<0967:PCOAHS>2.0.CO
[3]  
2
[4]  
ARNOLD S, 1992, PM10 STANDARDS NONTR, P13
[5]   TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations [J].
Ayers, GP ;
Keywood, MD ;
Gras, JL .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (22) :3717-3721
[6]   Development and evaluation of a continuous ambient PM2.5 mass monitor [J].
Babich, P ;
Wang, PY ;
Allen, G ;
Sioutas, C ;
Koutrakis, P .
AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (04) :309-324
[7]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[8]   ACUTE RESPIRATORY EFFECTS OF PARTICULATE AIR-POLLUTION [J].
DOCKERY, DW ;
POPE, CA .
ANNUAL REVIEW OF PUBLIC HEALTH, 1994, 15 :107-132
[9]  
DUTCHER D, 1999, INSTRUMENT INTERCOMP
[10]   A BETA-GAUGE METHOD APPLIED TO AEROSOL SAMPLES [J].
JAKLEVIC, JM ;
GATTI, RC ;
GOULDING, FS ;
LOO, BW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (06) :680-686