Reliability of linear alveolar bone loss measurements of mandibular posterior teeth from digitized bitewing radiographs

被引:15
作者
Hildebolt, CF
Pilgram, TK
Yokoyama-Crothers, N
Fletcher, G
Helbig, JL
Bartlett, TQ
Gravier, M
Vannier, MW
Shrout, MK
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Anthropol, St Louis, MO 63130 USA
[3] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[4] Med Coll Georgia, Dept Oral Diag & Patient Serv, Augusta, GA 30912 USA
关键词
alveolar bone; radiographic bone height; reliability;
D O I
10.1111/j.1600-051X.1998.tb02381.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Observer reliability in performing linear measurements between the cementoenamel junction and alveolar crest was determined for mandibular posterior teeth from digitized clinical bitewing radiographs acquired during recall examinations. 6 measurements (corresponding to traditional probing measurements) were made per tooth by 3 observers. Mesial and distal measurements made to the most coronal aspects of the alveolar crest were the most reliable and least biased. As was anticipated, intra-observer reliability tvas better than inter-observer reliability although the 3 observers of our study were able to detect a significant mean change (0.1 mm, p<0.0001) in alveolar bone height over a 1-year period for 10 patients. For our most reliable and unbiased measurements (mesial measurements to the alveolar crest), a change of 0.54 mm (90th percentile) would be required to indicate change at a site from one time to the next. Based on the reliability of our digital radiographic measurements, with the alpha error rate set at 0.05 and beta at 0.20, a difference in alveolar bone height of 0.3 mm could be detected with a patient sample size of between 13 (best case) and 54 (worst case).
引用
收藏
页码:850 / 856
页数:7
相关论文
共 37 条
[31]   NEW CONCEPTS OF DESTRUCTIVE PERIODONTAL-DISEASE [J].
SOCRANSKY, SS ;
HAFFAJEE, AD ;
GOODSON, JM ;
LINDHE, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (01) :21-32
[32]   EFFECT OF CONTROLLED ORAL HYGIENE PROCEDURES ON PROGRESSION OF PERIODONTAL DISEASE IN ADULTS - RESULTS AFTER THIRD AND FINAL YEAR [J].
SUOMI, JD ;
GREENE, JC ;
VERMILLION, JR ;
DOYLE, J ;
CHANG, JJ ;
LEATHERWOOD, EC .
JOURNAL OF PERIODONTOLOGY, 1971, 42 (03) :152-+
[33]  
VONWOWERN N, 1985, SCAND J DENT RES, V93, P162
[34]   BONE-MINERAL CONTENT BY PHOTON-ABSORPTIOMETRY OF THE MANDIBLE COMPARED WITH THAT OF THE FOREARM AND THE LUMBAR SPINE [J].
VONWOWERN, N ;
STORM, TL ;
OLGAARD, K .
CALCIFIED TISSUE INTERNATIONAL, 1988, 42 (03) :157-161
[35]   A COMPUTERIZED SYSTEM TO MEASURE INTERPROXIMAL ALVEOLAR BONE LEVELS IN EPIDEMIOLOGIC, RADIOGRAPHIC INVESTIGATIONS .2. INTRA-EXAMINER AND INTER-EXAMINER VARIATION STUDY [J].
WOUTERS, FR ;
LAVSTEDT, S ;
FRITHIOF, L ;
SODER, PO ;
HELLDEN, L ;
SALONEN, L .
ACTA ODONTOLOGICA SCANDINAVICA, 1988, 46 (01) :33-39
[36]   REPRODUCIBILITY OF AN ELECTRONIC PROBE IN RELATIVE ATTACHMENT LEVEL MEASUREMENTS [J].
YANG, MCK ;
MARKS, RG ;
MAGNUSSON, I ;
CLOUSER, B ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (08) :541-548
[37]  
[No title captured]