The antiproton depth-dose curve measured with alanine detectors

被引:24
作者
Bassler, Niels [1 ,2 ]
Hansen, Johnny W. [3 ]
Palmans, Hugo [4 ]
Holzscheiter, Michael H. [5 ]
Kovacevic, Sandra [6 ]
机构
[1] Aarhus Univ Hosp, Dept Expt Clin Oncol, DK-8000 Aarhus, Denmark
[2] Deutsch Krebsforschungszentrum, D-6900 Heidelberg, Germany
[3] Vejle Hosp, Vejle, Denmark
[4] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[5] Univ New Mexico, Albuquerque, NM 87131 USA
[6] Univ Montenegro, Podgorica, Montenegro
关键词
alanine; antiproton annihilation; mixed radiation field dosimetry;
D O I
10.1016/j.nimb.2008.01.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper we report on the measurement of the antiproton depth-dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen and Olsen for conversion of calculated dose into response. A good agreement is observed between the measured and calculated relative effectiveness although an underestimation of the measured values beyond the Bragg-peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use of the alanine detectors for dosimetry of mixed radiation fields. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:929 / 936
页数:8
相关论文
共 47 条
[1]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[2]   The antiproton depth-dose curve in water [J].
Bassler, N. ;
Holzscheiter, M. H. ;
Jaekel, O. ;
Knudsen, H. V. ;
Kovacevic, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03) :793-805
[3]  
BASSLER N, 2006, THESIS AARHUS U MAY
[4]   Dosimetry of low-energy protons and light ions [J].
Besserer, J ;
Bilski, P ;
de Boer, J ;
Kwiecien, T ;
Moosburger, M ;
Olko, P ;
Quicken, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :473-485
[5]   The effect of free-electron collection on the recombination correction to ionization measurements of pulsed radiation [J].
Boag, JW ;
Hochhauser, E ;
Balk, OA .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05) :885-897
[6]   CURRENT COLLECTION AND IONIC RECOMBINATION IN SMALL CYLINDRICAL IONIZATION CHAMBERS EXPOSED TO PULSED RADIATION [J].
BOAG, JW ;
CURRANT, J .
BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (629) :471-478
[7]   USE OF ALANINE AS A SOLID DOSIMETER [J].
BRADSHAW, WW ;
SPETZLER, HA ;
CADENA, DG ;
CRAWFORD, GW .
RADIATION RESEARCH, 1962, 17 (01) :11-+
[8]   THEORY OF RBE FOR HEAVY ION BOMBARDMENT OF DRY ENZYMES AND VIRUSES [J].
BUTTS, JJ ;
KATZ, R .
RADIATION RESEARCH, 1967, 30 (04) :855-&
[9]  
Chang, STOPPING POWER RANGE
[10]  
FASSO A, 2003, COMP HIGH EN NUCL PH