The antiproton depth-dose curve in water

被引:21
作者
Bassler, N. [1 ,2 ]
Holzscheiter, M. H. [3 ]
Jaekel, O. [2 ]
Knudsen, H. V. [4 ]
Kovacevic, S. [5 ]
机构
[1] Aarhus Univ Hosp, Dept Expt Clin Oncol, DK-8000 Aarhus, Denmark
[2] Deutsch Krebsforschungszentrum, D-6900 Heidelberg, Germany
[3] Univ New Mexico, Albuquerque, NM 87131 USA
[4] Univ Aarhus, Dept Phys & Astron, Aarhus, Denmark
[5] Univ Montenegro, Podgorica, Montenegro
关键词
D O I
10.1088/0031-9155/53/3/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have measured the depth-dose curve of 126 MeV antiprotons in a water phantom using ionization chambers. Since the antiproton beam provided by CERN has a pulsed structure and possibly carries a high-LET component from the antiproton annihilation, it is necessary to correct the acquired charge for ion recombination effects. The results are compared with Monte Carlo calculations and were found to be in good agreement. Based on this agreement we calculate the antiproton depth-dose curve for antiprotons and compare it with that for protons and find a doubling of the physical dose in the peak region for antiprotons.
引用
收藏
页码:793 / 805
页数:13
相关论文
共 32 条
[1]  
AGNEW LE, 1960, MEV PHYS REV, P1371
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[4]  
[Anonymous], 2005, CERN2005010
[5]  
Bassler N, 2005, AIP CONF PROC, V796, P423, DOI 10.1063/1.2130206
[6]  
Bassler N., 2006, THESIS AARHUS U
[7]  
BASSLER N, 2007, PBAR DATA
[8]   Bubble detector measurements of a mixed radiation field from antiproton annihilation [J].
Bassler, Niels ;
Knudsen, Helge ;
Moller, Soren Pape ;
Petersen, Jorgen B. ;
Rahbek, Dennis ;
Uggerhoi, Ulrik I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (01) :269-273
[9]   Physical and biophysical characteristics of a fully modulated 72 MeV therapeutic proton beam: model predictions and experimental data [J].
Biaggi, M ;
Ballarini, F ;
Burkard, W ;
Egger, E ;
Ferrari, A ;
Ottolenghi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 159 (1-2) :89-100
[10]   The effect of free-electron collection on the recombination correction to ionization measurements of pulsed radiation [J].
Boag, JW ;
Hochhauser, E ;
Balk, OA .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05) :885-897