Automation of liquid-liquid extraction-spectrophotometry using prolonged pseudo-liquid drops and handheld CCD for speciation of Cr(VI) and Cr(III) in water samples

被引:44
作者
Chen, W [1 ]
Zhong, GP [1 ]
Zhou, ZD [1 ]
Wu, P [1 ]
Hou, XD [1 ]
机构
[1] Sichuan Univ, Coll Chem, Key Lab Green Chem & Technol MOE, Chengdu 610064, Sichuan, Peoples R China
关键词
D O I
10.2116/analsci.21.1189
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple spectrophotometric system, based on a prolonged pseudo-liquid drop device as an optical cell and a handheld charge coupled device (CCD) as a detector, was constructed for automatic liquid-liquid extraction and spectrophotometric speciation of trace Cr(VI) and Cr(III) in water samples. A tungsten halogen lamp was used as the light source, and a laboratory-constructed T-tube with two open ends was used to form the prolonged pseudo-liquid drop inside the tube. In the medium of perchloric acid solution, Cr(VI) reacted with 1,5-diphenylcarbazide (DPC); the formed complex was automatically extracted into n-pentanol, with a preconcentration ratio of about 5. The organic phase with extracted chromium complex was then pumped through the optical cell for absorbance measurement at 548 nm. Under optimal conditions, the calibration curve was linear in the range of 7.5 - 350 mu g L-1, with a correlation coefficient of 0.9993. The limit of detection (3 sigma) was 7.5 mu g L-1. That Cr(III) species cannot react with DPC, but can be oxidized to Cr(VI) prior to determination, is the basis of the speciation analysis. The proposed speciation analysis was sensitive, yet simple, labor-effective, and cost-effective. It has been preliminarily applied for the speciation of Cr(VI) and Cr(III) in spiked river and tap water samples. It can also be used for other automatic liquid-liquid extraction-spectrophotometric determinations.
引用
收藏
页码:1189 / 1193
页数:5
相关论文
共 39 条
[1]   Preconcentration and speciation of chromium in waters using solid-phase extraction and atomic absorption spectrometry [J].
Adriá-Cerezo, DM ;
Llobat-Estellés, M ;
Maurí-Aucejo, AR .
TALANTA, 2000, 51 (03) :531-536
[2]   ESSENTIALITY OF CHROMIUM IN HUMANS [J].
ANDERSON, RA .
SCIENCE OF THE TOTAL ENVIRONMENT, 1989, 86 (1-2) :75-81
[3]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]  
ARTHUR CL, 1992, LC GC-MAG SEP SCI, V10, P656
[5]   A new cation-exchange method for accurate field speciation of hexavalent chromium [J].
Ball, JW ;
McCleskey, RB .
TALANTA, 2003, 61 (03) :305-313
[6]   SOLVENT-EXTRACTION IN CONTINUOUS-FLOW INJECTION ANALYSIS - DETERMINATION OF MOLYBDENUM IN PLANT MATERIAL [J].
BERGAMIN, H ;
MEDEIROS, JX ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1978, 101 (01) :9-16
[7]   Development of a new system for the speciation of chromium in natural waters and human urine samples by combining ion exchange and ETA-AAS [J].
Cordero, MTS ;
Alonso, EIV ;
de Torres, AG ;
Pavón, JMC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (03) :398-403
[8]   Electromigration injection from a small loop in capillary electrophoresis [J].
Dasgupta, PK ;
Surowiec, K .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4291-4299
[9]   MEMBRANE APPROACH TO SOLID-PHASE EXTRACTIONS [J].
HAGEN, DF ;
MARKELL, CG ;
SCHMITT, GA ;
BLEVINS, DD .
ANALYTICA CHIMICA ACTA, 1990, 236 (01) :157-164
[10]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640