Acoustic Radiation Force Impulse-Imaging for the evaluation of the thyroid gland: A limited patient feasibility study

被引:95
作者
Friedrich-Rust, Mireen [1 ]
Romenski, Olga [1 ]
Meyer, Gesine [1 ]
Dauth, Nina [1 ]
Holzer, Katharina [2 ]
Gruenwald, Frank [3 ]
Kriener, Susanne [4 ]
Herrmann, Eva [5 ]
Zeuzem, Stefan [1 ]
Bojunga, Joerg [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Internal Med 1, Frankfurt, Germany
[2] JW Goethe Univ Hosp, Dept Gen & Visceral Surg, Frankfurt, Germany
[3] JW Goethe Univ Hosp, Dept Nucl Med, Frankfurt, Germany
[4] JW Goethe Univ Hosp, Inst Pathol, Frankfurt, Germany
[5] JW Goethe Univ Hosp, Inst Biostat & Math Modelling, Fac Med, Frankfurt, Germany
关键词
Sonography; Thyroid cancer; Radionuclide scanning; ARFI; RTE; FINE-NEEDLE-ASPIRATION; DIFFERENTIAL-DIAGNOSIS; IN-VIVO; NODULES; ELASTOGRAPHY; ULTRASOUND; MALIGNANCY; BENIGN; ELASTICITY; METAANALYSIS;
D O I
10.1016/j.ultras.2011.06.012
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Purpose: Real-time tissue elastography, a qualitative elastography method, has shown promising results in the diagnostic work up of thyroid nodules. However, to our knowledge no study has evaluated a quantitative elastography method in the thyroid gland. The present study is a feasibility study evaluating Acoustic Radiation Force Impulse-Imaging, a novel quantitative elastography method in the thyroid gland. Methods: ARFI-imaging involves the mechanical excitation of tissue using short-duration acoustic pulses to generate localized displacements in tissue. The displacements induce a lateral shear-wave propagation which is tracked using multiple laterally positioned ultrasound "tracking" beams. Inclusion criteria were: thyroid nodules >= 1 cm, non-functioning or hypo-functioning on radionuclide scanning, and cytological/histological assessment of thyroid nodule as reference method. All patients received conventional ultrasound, and examination of the thyroid gland including Power Doppler Ultrasound using a 9 MHz linear transducer, in addition real-time elastography (RTE) was performed at 9 MHz frequency and ARFI-imaging was performed at 4 MHz using Siemens (ACUSON S2000) B-mode-ARFI combination transducer. Results: Sixty nodules in 55 patients were analyzed. Three nodules were papillary carcinoma. The stiffer the tissue the faster the shear wave propagates. The results obtained indicated that the shear wave velocity in thyroid lobes ranged between 0.5 and 4.9 m/s. The median velocity of ARFI-imaging in the healthy nodule-free thyroid gland, as well as in benign and malignant thyroid nodules was 1.98 m/s (range: 1.20-3.63 m/s), 2.02 m/s (range: 0.92-3.97 m/s), and 4.30 m/s (range: 2.40-4.50 m/s), respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.018) or benign thyroid nodules (p = 0.014) on the other hand. Specificity of ARFI-imaging for the differentiation of benign and malignant thyroid nodules was comparable with RTE (91-95%). Conclusions: ARFI can be performed in the thyroid tissue with reliable results. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 31 条
[1]
The spectrum of thyroid disorders in an iodine-deficient community: The Pescopagano survey [J].
Aghini-Lombardi, F ;
Antonangeli, L ;
Martino, E ;
Vitti, P ;
Maccherini, D ;
Leoli, F ;
Rago, T ;
Grasso, L ;
Valeriano, R ;
Balestrieri, A ;
Pinchera, A .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1999, 84 (02) :561-566
[2]
[Anonymous], MOD PATHOL
[3]
[Anonymous], 2003, J ULTRASOUND MED, V22, P1126
[4]
US-elastography in the differential diagnosis of benign and malignant thyroid nodules [J].
Asteria, Carmela ;
Giovanardi, Alessandra ;
Pizzocaro, Alessandro ;
Cozzaglio, Luca ;
Morabito, Alberto ;
Somalvico, Francesco ;
Zoppo, Adele .
THYROID, 2008, 18 (05) :523-531
[5]
Real-Time Elastography for the Differentiation of Benign and Malignant Thyroid Nodules: A Meta-Analysis [J].
Bojunga, Joerg ;
Herrmann, Eva ;
Meyer, Gesine ;
Weber, Sonja ;
Zeuzem, Stefan ;
Friedrich-Rust, Mireen .
THYROID, 2010, 20 (10) :1145-1150
[6]
Thyroid nodule shape suggests malignancy [J].
Cappelli, Carlo ;
Castellano, Maurizio ;
Pirola, Ilenia ;
Gandossi, Elena ;
De Martino, Elvira ;
Cumetti, Davide ;
Agosti, Barbara ;
Rosei, Enrico Agabiti .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2006, 155 (01) :27-31
[7]
Dietlein M, 2003, EUR J ENDOCRINOL, V148, P377, DOI 10.1530/eje.0.1480377
[8]
Frey H, 2003, RADIOLOGE, V43, P850, DOI 10.1007/s00117-003-0943-2
[9]
Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[10]
Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen [J].
Gallotti, A. ;
D'Onofrio, M. ;
Mucelli, R. Pozzi .
RADIOLOGIA MEDICA, 2010, 115 (06) :889-897