Characterization of a new qQq-FTICR mass spectrometer for post-translational modification analysis and top-down tandem mass Spectrometry of whole proteins

被引:48
作者
Jebanathirajah, JA
Pittman, JL
Thomson, BA
Budnik, BA
Kaur, P
Rape, M
Kirschner, M
Costello, CE
O'Connor, PB
机构
[1] Boston Univ, Dept Biochem, Sch Med, Boston, MA 02118 USA
[2] MDS SCIEX, Concord, ON, Canada
[3] Boston Univ, Sch Med, Cardiovasc Proteom Ctr, Boston, MA 02215 USA
[4] Harvard Univ, Sch Med, Dept Syst Biol, Boston, MA 02115 USA
关键词
D O I
10.1016/j.jasms.2005.08.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of a new electrospray qQq Fourier transform ion cyclotron mass spectrometer (qQq-FTICR MS) instrument for biologic applications is described. This qQq-FTICR mass spectrometer was designed for the study of post-translationally modified proteins and for top-down analysis of biologically relevant protein samples. The utility of the instrument for the analysis of phosphorylation, a common and important post-translational modification, was investigated. Phosphorylation was chosen as an example because it is ubiquitous and challenging to analyze. In addition, the use of the instrument for top-down sequencing of proteins was explored since this instrument offers particular advantages to this approach. Top-down sequencing was performed on different proteins, including commercially available proteins and biologically derived samples such as the human E2 ubiquitin conjugating enzyme, UbCH10. A good sequence tag was obtained for the human UbCH10, allowing the unambiguous identification of the protein. The instrument was built with a commercially produced front end: a focusing rf-only quadrupole (Q0), followed by a resolving quadrupole (Q1), and a LINAC quadrupole collision cell (Q2), in combination with an FTICR mass analyzer. It has utility in the analysis of samples found in substoichiometric concentrations, as ions can be isolated in the mass resolving Q1 and accumulated in Q2 before analysis in the ICR cell. The speed and efficacy of the Q2 cooling and fragmentation was demonstrated on an LCMS-compatible time scale, and detection limits for phosphopeptides in the 10 amol/mu L range (pM) were demonstrated. The instrument was designed to make several fragmentation methods available, including nozzle-skimmer fragmentation, Q2 collisionally activated dissociation (Q2 CAD), multipole storage assisted dissociation (MSAD), electron capture dissociation (ECD), infrared multiphoton induced dissociation (IRMPD), and sustained off resonance irradiation (SORI) CAD, thus allowing a variety of MSn experiments. A particularly useful aspect of the system was the use of Q1 to isolate ions from complex mixtures with narrow windows of isolation less than I m/z. These features enable top-down protein analysis experiments as well structural characterization of minor components of complex mixtures.
引用
收藏
页码:1985 / 1999
页数:15
相关论文
共 75 条
[1]   Electron capture dissociation in a radio frequency ion trap [J].
Baba, T ;
Hashimoto, Y ;
Hasegawa, H ;
Hirabayashi, A ;
Waki, I .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4263-4266
[2]   Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization [J].
Belov, ME ;
Anderson, GA ;
Angell, NH ;
Shen, YF ;
Tolic, N ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5052-5060
[3]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[4]   Electron detachment dissociation of peptide di-anions: an electron-hole recombination phenomenon [J].
Budnik, BA ;
Haselmann, KF ;
Zubarev, RA .
CHEMICAL PHYSICS LETTERS, 2001, 342 (3-4) :299-302
[5]   Utility of accurate mass tags for proteome-wide protein identification [J].
Conrads, TP ;
Anderson, GA ;
Veenstra, TD ;
Pasa-Tolic, L ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3349-3354
[6]   Time, life ... and mass spectrometry - New techniques to address biological questions [J].
Costello, CE .
BIOPHYSICAL CHEMISTRY, 1997, 68 (1-3) :173-188
[7]   Deamidation: Differentiation of aspartyl from isoaspartyl products in peptides by electron capture dissociation [J].
Cournoyer, JJ ;
Pittman, JL ;
Ivleva, VB ;
Fallows, E ;
Waskell, L ;
Costello, CE ;
O'Connor, PB .
PROTEIN SCIENCE, 2005, 14 (02) :452-463
[8]   Improved molecular weight-based processing of intact proteins for interrogation by quadrupole-enhanced FT MS/MS [J].
Du, Y ;
Meng, FY ;
Patrie, SM ;
Miller, LM ;
Kelleher, NL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (04) :801-806
[9]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[10]   Targeted analysis and discovery of posttranslational modifications in proteins from methanogenic archaea by top-down MS [J].
Forbes, AJ ;
Patrie, SM ;
Taylor, GK ;
Kim, YB ;
Jiang, LH ;
Kelleher, NL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (09) :2678-2683