Ozone measurement with passive samplers: Validation and use for ozone pollution assessment in Montpellier, France

被引:37
作者
Bernard, NL [1 ]
Gerber, MJ [1 ]
Astre, CM [1 ]
Saintot, MJ [1 ]
机构
[1] INSERM, CRLC, Canc Res Ctr, Grp Epidemiol Metab, F-34298 Montpellier 5, France
关键词
D O I
10.1021/es971140k
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this pilot study was to determine a way of assessing personal exposure to ozone (O-3) for use in a study of O-3 effects on health. Passive samplers (Passam, AG) were used to measure pollution levels in Montpellier, France. They were standardized using an O-3 analyzer. Blanks and duplicates were tested to evaluate sensitivity (6.6 mu g/ m(3)) and imprecision (2 mu g/m(3)). They were validated by comparing on-site measurements with those of the automatic UV absorption analyzers of the regional air quality network (AMPADI-LR). The correlation coefficient was r = 0.9, p < 10(-3), and the regression coefficient was close to 1. The on-site measurements provided information about local pollution. Distance from NO2 sources turban traffic) and sunlight intensity were identified as environmental determinants of O-3 pollution. Residential microenvironmental concentrations and personal exposure were measured for 110 subjects. The indoor/outdoor ratio is higher than in Mexico City and higher than in Toronto in summer but comparable with that in Toronto in winter. The relationship between personal exposure and indoor home measurements is closer than that between personal exposure and outdoor home environment measurements. This is especially true for the spring and summer months, when the correlation between indoor and outdoor measurements is low (r = 0.23, p < 0.05). At the workplace, on the other hand, there is a close correlation between indoor and outdoor ozone measurements in summer (r = 0.80, p < 0.001), as there is between personal exposure and outdoor measurements (r = 0.60, p < 0.001).
引用
收藏
页码:217 / 222
页数:6
相关论文
共 18 条
[1]  
*AC SCI I FRANC, 1993, 30 I FRANC ACAD SCI
[2]  
ASCENCIO E, 1984, MINISTERE URBANISME, V4, P37
[3]  
Bernard NL, 1997, J EXPO ANAL ENV EPID, V7, P165
[4]   PERSONAL AND FIXED-SITE OZONE MEASUREMENTS WITH A PASSIVE SAMPLER [J].
BRAUER, M ;
BROOK, JR .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (07) :529-537
[5]   A PASSIVE SAMPLER FOR ATMOSPHERIC OZONE [J].
GROSJEAN, D ;
HISHAM, MWM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1992, 42 (02) :169-173
[6]  
HANDGARTNER M, 1995, 10 WORLD CLEAN AIR C
[7]  
HEMON D, 1995, REV EPIDEMIOL SANTE, V43, P395
[8]  
Kinney P.L., 1993, APPL OCCUP ENV HYG, V8, P267
[9]   MEASUREMENT OF AMBIENT OZONE USING A NITRITE-COATED FILTER [J].
KOUTRAKIS, P ;
WOLFSON, JM ;
BUNYAVIROCH, A ;
FROEHLICH, SE ;
HIRANO, K ;
MULIK, JD .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :209-214
[10]  
KOUTRAKIS P, 1990, P 1990 EPA A WMA C M