Efficient applications of capillary electrophoresis-tandem mass spectrometry to the analysis of adrenoreceptor antagonist enantiomers using a partial filling technique
被引:24
作者:
Grard, S
论文数: 0引用数: 0
h-index: 0
机构:Univ Orleans, CNRS UMR 6005, Inst Chim Organ & Analyt, F-45067 Orleans, France
Grard, S
Morin, P
论文数: 0引用数: 0
h-index: 0
机构:Univ Orleans, CNRS UMR 6005, Inst Chim Organ & Analyt, F-45067 Orleans, France
Morin, P
Dreux, M
论文数: 0引用数: 0
h-index: 0
机构:Univ Orleans, CNRS UMR 6005, Inst Chim Organ & Analyt, F-45067 Orleans, France
Dreux, M
Ribet, JP
论文数: 0引用数: 0
h-index: 0
机构:Univ Orleans, CNRS UMR 6005, Inst Chim Organ & Analyt, F-45067 Orleans, France
Ribet, JP
机构:
[1] Univ Orleans, CNRS UMR 6005, Inst Chim Organ & Analyt, F-45067 Orleans, France
[2] Ctr Rech Pierre Fabre, Dept Chim Analyt, F-81106 Castres, France
partial-filling capillary electrophoresis;
enantiomer separation;
mass spectrometry;
cyclodextrins;
D O I:
10.1016/S0021-9673(01)01005-6
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Throughout the separation of chiral basic drugs by capillary electrophoresis (CE) with neutral hydroxypropyl-beta -pcyclodextrin (HP-beta -CD) as chiral selector, the sensitivity of detection can be improved by using tandem mass spectrometric (MS-MS) detection with a partial filling technique rather than with UV spectrometric detection. Prior to sample injection, the capillary was partly filled with HP-beta -CD dissolved in volatile ammonium formate buffer (pH 4, ionic strength 50 mM). The effects of modifying the HP-beta -CD concentration in the selector zone and the length of the separation zone on the enantioresolution and the signal-to-noise ratio of the pseudo-molecular MH+ ion were investigated. For a given selector zone length, as the concentration of the neutral cyclodextrin increases, the resolution between enantiomers becomes higher (the opposite of the behavior of the signal-to-noise ratio) and then reaches an optimum value. The decrease of the selector zone length lowered the resolution between the enantiomers but increased peak efficiencies and signal-to-noise ratio values. Accordingly, partial capillary filling at 80% (v/v) and 10 mM concentration of HP-beta -CD was selected as a suitable compromise between resolution and sensitivity of MS detection. Limits of detection for each adrenoreceptor antagonist enantiomer were 5 ng/ml (0.02 muM) in CE-MS-MS instead of 150 ng/ml (0.60 muM) in CE-UV, which enhances sensitivity by a factor of 30. (C) 2001 Elsevier Science B.V. All rights reserved.