Comparison of the aerosol velocity and spray duration of Respimat® Soft Mist™ Inhaler and pressurized metered dose inhalers

被引:142
作者
Hochrainer, D [1 ]
Hölz, H [1 ]
Kreher, C [1 ]
Scaffidi, L [1 ]
Spallek, M [1 ]
Wachtel, H [1 ]
机构
[1] Boehringer Ingelheim Pharma GmbH & Co KG, D-55216 Ingelheim, Germany
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2005年 / 18卷 / 03期
关键词
Respimat; aerosol; velocity; spray; spray duration; inhaler; metered dose inhaler; MDI;
D O I
10.1089/jam.2005.18.273
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Apart from particle size distribution, spray velocity is one of the most important aerosol characteristics that influence lung deposition of inhaled drugs. The time period over which the aerosol is released (spray duration) is also important for coordination of inhalation. Respimat (R) Soft Mist (TM) Inhaler (SMI) is a new generation, propellant-free inhaler that delivers drug to the lung much more efficiently than pressurised metered dose inhalers (pMDIs). The objective of this study was to compare the velocity and spray duration of aerosol clouds produced by Respimat (R) SMI with those from a variety of chlorofluorocarbon (CFC) and hydrofluoroalkane (HFA) pMDIs. All inhalers contained solutions or suspensions of bronchodilators. A videorecording method was used to determine the aerosol velocity. For spray duration, the time for generation of the Soft Mist (TM) by Respimat (R) SMI was initially determined using three different methods (videorecording [techniques A and B], laser light diffraction and rotating disc). Videorecording was then used to compare the spray duration of Respimat (R) SMI with those from the other inhalers. The Soft Mist (TM) produced by Respimat (R) SMI moved much more slowly and had a more prolonged duration than aerosol clouds from pMDIs (mean velocity at a 10-cm distance from the nozzle: Respimat (R) SMI, 0.8 m/sec; pMDIs, 2.0-8.4 m/sec; mean duration: Respimat (R) SMI, 1.5 sec; pMDIs, 0.15-0.36 sec). These characteristics should result in improved lung and reduced oropharyngeal deposition, and are likely to simplify coordination of inhaler actuation and inhalation compared with pMDIs.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 19 条
[1]  
[Anonymous], [No title captured]
[2]   A review of the development of Respimat® Soft Mist™ Inhaler [J].
Dalby, R ;
Spallek, M ;
Voshaar, T .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 283 (1-2) :1-9
[3]   Design and application of a new modular adapter for laser diffraction characterization of inhalation aerosols [J].
de Boer, AH ;
Gjaltema, D ;
Hagedoorn, P ;
Schaller, M ;
Witt, W ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 249 (1-2) :233-245
[4]   Characterization of inhalation aerosols: a critical evaluation of cascade impactor analysis and laser diffraction technique [J].
de Boer, AH ;
Gjaltema, D ;
Hagedoorn, P ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 249 (1-2) :219-231
[5]   HIGH-SPEED PHOTOGRAPHIC ANALYSIS OF AEROSOLS PRODUCED BY METERED DOSE INHALERS [J].
DHAND, R ;
MALIK, SK ;
BALAKRISHNAN, M ;
VERMA, SR .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1988, 40 (06) :429-430
[6]   General factors influencing drug delivery to the lung [J].
Ganderton, D .
RESPIRATORY MEDICINE, 1997, 91 :13-16
[7]  
HEYDER J, 1990, NEUE WEGE INHALATION
[8]   Improved delivery of ipratropium bromide/fenoterol from Respimat® Soft Mist™ Inhaler in patients with COPD [J].
Kilfeather, SA ;
Ponitz, HH ;
Beck, E ;
Schmidt, P ;
Lee, A ;
Bowen, I ;
Hesse, C .
RESPIRATORY MEDICINE, 2004, 98 (05) :387-397
[9]  
Kohler D., 2000, THEORIE PRAXIS INHAL
[10]   Lung deposition of fenoterol and flunisolide delivered using a novel device for inhaled medicines - Comparison of RESPIMAT with conventional metered-dose inhalers with and without spacer devices [J].
Newman, SP ;
Brown, J ;
Steed, KP ;
Reader, SJ ;
Kladders, H .
CHEST, 1998, 113 (04) :957-963