No delayed restenosis at 18 months after implantation of sirolimus-eluting stent

被引:11
作者
Tanabe, K [1 ]
Degertekin, M [1 ]
Regar, E [1 ]
Ligthart, JMR [1 ]
van der Giessen, WJ [1 ]
Serruys, PW [1 ]
机构
[1] Univ Rotterdam Hosp, Thoraxctr, Dept Cardiol, Rotterdam, Netherlands
关键词
stents; restenosis; drugs;
D O I
10.1002/ccd.10266
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sirolimus-eluting stent is emerging as a potential solution for the prevention of restenosis. Recently, a sustained suppression of neointimal proliferation 12 months after implantation of this stent was reported. This is the first report of angiographic and IVUS images 18 months after the implantation of a sirolimus-eluting stent. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 10 条
[1]   Edge restenosis after implantation of high activity 32P radioactive β-emitting stents [J].
Albiero, R ;
Nishida, T ;
Adamian, M ;
Amato, A ;
Vaghetti, M ;
Corvaja, N ;
Di Mario, C ;
Colombo, A .
CIRCULATION, 2000, 101 (21) :2454-2457
[2]   Late coronary occlusion after intracoronary brachytherapy [J].
Costa, MA ;
Sabaté, M ;
van der Giessen, WJ ;
Kay, IP ;
Cervinka, P ;
Ligthart, JMR ;
Serrano, P ;
Coen, VLMA ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 1999, 100 (08) :789-792
[3]   Inhibition of intimal thickening after balloon angioplasty in porcine coronary arteries by targeting regulators of the cell cycle [J].
Gallo, R ;
Padurean, A ;
Jayaraman, T ;
Marx, S ;
Rogue, M ;
Adelman, S ;
Chesebro, J ;
Fallon, J ;
Fuster, V ;
Marks, A ;
Badimon, JJ .
CIRCULATION, 1999, 99 (16) :2164-2170
[4]  
Kay IP, 2001, CIRCULATION, V103, P14
[5]  
Kozuma K, 1999, J INVASIVE CARDIOL, V11, P651
[6]   RAPAMYCIN-FKBP INHIBITS CELL-CYCLE REGULATORS OF PROLIFERATION IN VASCULAR SMOOTH-MUSCLE CELLS [J].
MARX, SO ;
JAYARAMAN, T ;
GO, LO ;
MARKS, AR .
CIRCULATION RESEARCH, 1995, 76 (03) :412-417
[7]   Rapamycin inhibits vascular smooth muscle cell migration [J].
Poon, M ;
Marx, SO ;
Gallo, R ;
Badimon, JJ ;
Taubman, MB ;
Marks, AR .
JOURNAL OF CLINICAL INVESTIGATION, 1996, 98 (10) :2277-2283
[8]   Sustained suppression of neointimal proliferation by sirolimus-eluting stents - One-year angiographic and intravascular ultrasound follow-up [J].
Sousa, JE ;
Costa, MA ;
Abizaid, AC ;
Rensing, BJ ;
Abizaid, AS ;
Tanajura, LF ;
Kozuma, K ;
Van Langenhove, G ;
Sousa, AGMR ;
Falotico, R ;
Jaeger, J ;
Popma, JJ ;
Serruys, PW .
CIRCULATION, 2001, 104 (17) :2007-2011
[9]   Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification [J].
vonBirgelen, C ;
Mintz, GS ;
Nicosia, A ;
Foley, DP ;
vanderGiessen, WJ ;
Bruining, N ;
Airiian, SG ;
Roelandt, JRTC ;
deFeyter, PJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (02) :436-443
[10]  
Wenguang L, 1991, Int J Card Imaging, V6, P247, DOI 10.1007/BF01797856