Magnetic resonance microimaging for noninvasive quantification of myocardial function and mass in the mouse

被引:141
作者
Ruff, J
Wiesmann, F
Hiller, KH
Voll, S
von Kienlin, M
Bauer, WR
Rommel, E
Neubauer, S
Haase, A
机构
[1] Univ Wurzburg, Med Klin, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Phys Inst EP5, D-97080 Wurzburg, Germany
[3] Univ Mannheim, Med Klin 2, Heidelberg, Germany
关键词
mouse heart; magnetic resonance imaging; myocardial mass; myocardial function;
D O I
10.1002/mrm.1910400106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to develop high-resolution cardiac magnetic resonance imaging techniques for the in vivo mouse model for quantification of myocardial function and mass. Eight male mice were investigated on a 7-Tesla MRI scanner. High-quality images in multiple short axis slices (inplane resolution 117 mu m(2), slice thickness 1 mm) were acquired with an EGG-gated cine sequence. Left ventricular end-diastolic and end-systolic volumes and mass were calculated from segmented slice volumes. There was precise agreement of left ventricular mass determined ex vivo and by MRI. Intraobserver (5%) and interobserver (5%) variability of in vivo MR measurements were low.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 19 条
[1]   MICROSPHERE AND DILUTION TECHNIQUES FOR THE DETERMINATION OF BLOOD FLOWS AND VOLUMES IN CONSCIOUS MICE [J].
BARBEE, RW ;
PERRY, BD ;
RE, RN ;
MURGO, JP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (03) :R728-R733
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[4]   QUANTIFICATION OF THE LEFT-VENTRICULAR VOLUMES AND FUNCTION WITH CINE MR-IMAGING - COMPARISON OF GEOMETRIC-MODELS WITH 3-DIMENSIONAL DATA [J].
DULCE, MC ;
MOSTBECK, GH ;
FRIESE, KK ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :371-376
[5]  
FIELD LJ, 1993, ANNU REV PHYSIOL, V55, P97
[6]   MEASUREMENT OF LEFT-VENTRICULAR MASS INVIVO USING GATED NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
FLORENTINE, MS ;
GROSSKREUTZ, CL ;
CHANG, W ;
HARTNETT, JA ;
DUNN, VD ;
EHRHARDT, JC ;
FLEAGLE, SR ;
COLLINS, SM ;
MARCUS, ML ;
SKORTON, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) :107-112
[7]   RAPID MEASUREMENT OF LEFT-VENTRICULAR MASS BY SPIN-ECHO MAGNETIC-RESONANCE-IMAGING [J].
FORBAT, SM ;
KARWATOWSKI, SP ;
GATEHOUSE, PD ;
FIRMIN, DN ;
LONGMORE, DB ;
UNDERWOOD, SR .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (793) :86-90
[8]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR MASS AND SYSTOLIC FUNCTION IN MICE [J].
GARDIN, JM ;
SIRI, FM ;
KITSIS, RN ;
EDWARDS, JG ;
LEINWAND, LA .
CIRCULATION RESEARCH, 1995, 76 (05) :907-914
[9]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[10]   IN-VIVO ECHOCARDIOGRAPHIC DETECTION OF ENHANCED LEFT-VENTRICULAR FUNCTION IN GENE-TARGETED MICE WITH PHOSPHOLAMBAN DEFICIENCY [J].
HOIT, BD ;
HOURY, SF ;
KRANIAS, EG ;
BALL, N ;
WALSH, RA .
CIRCULATION RESEARCH, 1995, 77 (03) :632-637