On-line solid-phase extraction liquid chromatography, particle beam mass spectrometry, and gas chromatography mass spectrometry of carbamate pesticides

被引:24
作者
Slobodnik, J
HoekstraOussoren, SJF
Jager, ME
Honing, M
vanBaar, BLM
Brinkman, UAT
机构
[1] CSIC,CID,DEPT ENVIRONM CHEM,BARCELONA 08034,SPAIN
[2] FREE UNIV AMSTERDAM,DEPT ORGAN & INORGAN CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
on-line solid-phase extraction; column liquid chromatography; gas chromatography; mass spectrometry; carbamate pesticides; environmental samples;
D O I
10.1039/an9962101327
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line solid-phase extraction-liquid chromatography-particle beam mass spectrometry (SPE-LC-PB-MS) was used to study 32 carbamates and 11 of their transformation products in environmental water samples, The analytes were enriched from 100 ml samples on Bondesil-C-18/OH, packed in a 10 mm x 3.0 mm id precolumn, eluted on-line with a gradient of methanol-0.1 mol l(-1) ammonium acetate to a C-18 analytical column and detected by PB-MS, Detection limits of 12 carbamates and five degradation products were 0.1-8 mu g l(-1) in surface water, using full-scan electron impact mode detection, The RSDs of the retention times were 0.05-0.2% and those of peak areas 5-35%, Twenty-eight analytes proved to be amenable to GC with detection limits of 0.05-3 ng injected on-column, When using the same mass spectrometer, the spectra obtained by LC-PB-MS and GC-MS were identical.
引用
收藏
页码:1327 / 1334
页数:8
相关论文
共 38 条
[1]  
APFFEL JA, 1991, J CHROMATOGR, V554, P102
[2]   LIQUID-CHROMATOGRAPHY - PARTICLE-BEAM MASS-SPECTROMETRY FOR IDENTIFICATION OF UNKNOWN POLLUTANTS IN WATER [J].
BAGHERI, H ;
SLOBODNIK, J ;
RECASENS, RMM ;
GHIJSEN, RT ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1993, 37 (3-4) :159-167
[3]   INVESTIGATION OF ENHANCED ION ABUNDANCES FROM A CARRIER PROCESS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
BELLAR, TA ;
BEHYMER, TD ;
BUDDE, WL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) :92-98
[4]   PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY USING A THERMOSPRAY SOURCE IN THE FILAMENT-ON MODE [J].
BERRY, AJ ;
GAMES, DE ;
MYLCHREEST, IC ;
PERKINS, JR ;
PLEASANCE, S .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (02) :105-109
[5]   TRACE-LEVEL DETECTION AND IDENTIFICATION OF POLAR PESTICIDES IN SURFACE-WATER - THE SAMOS APPROACH [J].
BRINKMAN, UAT ;
SLOBODNIK, J ;
VREULS, JJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :373-381
[6]   DETERMINATION OF ACIDIC AND BASIC NEUTRAL PESTICIDES IN WATER WITH A NEW MICROLITER FLOW-RATE LC/MS PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1416-1423
[7]   DETERMINATION OF PESTICIDES IN DRINKING-WATER BY ONLINE SOLID-PHASE DISK EXTRACTION FOLLOWED BY VARIOUS LIQUID-CHROMATOGRAPHIC SYSTEMS [J].
CHIRON, S ;
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :125-134
[8]   PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - INSTRUMENTATION AND APPLICATIONS - A REVIEW [J].
CREASER, CS ;
STYGALL, JW .
ANALYST, 1993, 118 (12) :1467-1480
[9]  
DEKOK A, 1992, J CHROMATOGR, V623, P265
[10]  
*EEC, 1980, EEC DRINK WAT GUID