Organic and inorganic selenium speciation in urine by on-line vesicle mediated high-performance liquid chromotography-focused microwave digestion-hydride generation-inductively coupled plasma mass spectrometry

被引:50
作者
LaFuente, JMG [1 ]
Dlaska, M [1 ]
Sanchez, MLF [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
vesicle mediated high-performance liquid chromatography; on-line focused microwave digestion; hydride generation; inductively coupled plasma mass spectrometry; human urine; basal selenium speciation;
D O I
10.1039/a707101i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A vesicle mediated high performance liquid chromatographic (HPLC)-microwave digestion (MW)-hydride generation (HG) system coupled on-line with atomic absorption spectrometry (AAS) and inductively coupled plasma mass spectrometry (ICP-MS) has been assessed for selenium species separation and detection, Selenocystine, selenomethionine, selenoethionine, selenourea, Se-IV and Se-VI are separated by vesicle mediated chromatography prior to on-line selenocompounds microwave digestion with a KBrO3-HBr mixture to generate Se-IV continuously, which is finally transformed into SeH2, in a continuous manner with a merging flow of sodium tetrahydroborate(III). Analytical characteristics of this coupling are compared with those obtained coupling HPLC-ICP-MS via conventional nebulisation, Detection limits (DLs) obtained for selenocystine, selenomethionine, selenoethionine, selenite and selenate in spiked human urine, when ICP-MS was used as detector, ranged between 1.0 and 5.3 mu g l(-1) (51-267 pg), while precision ranged between +/- 3.4 and +/- 8.4%. This continuous system, vesicle mediated HPLC-MW-HG-atomic detection, allows the separation and detection of selenocystine, selenourea, selenomethionine, selenoethionine, selenite and selenate in human urine. The analytical versatility of such coupling (with ICP-MS as the atomic detector) allows basal selenium speciation in urine, Three different normally occurring selenium species in human urine, simply diluted (1 + 1), have been found, The relative sophistication of the vesicle mediated-HPLC-MW-HG-ICP-MS interface, versus HPLC-ICP-MS via conventional nebulisation, can be justified because of its considerably higher sensitivity for most of the selenocompounds assayed, lower matrix interferences and the possibility of simultaneous interference free Se-77 and Se-78 monitoring.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 23 条
[11]   Speciation of inorganic selenium and selenoaminoacids by on-line reversed-phase high-performance liquid chromatography focused microwave digestion hydride generation atomic detection [J].
Lafuente, JMG ;
Sanchez, MLF ;
SanzMedel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1163-1169
[12]  
LaFuente JMG, 1996, SPECTROCHIM ACTA B, V51, P1849
[13]  
LOBINSKY R, COMMUNICATION
[14]  
MarchanteGayon JM, 1996, FRESEN J ANAL CHEM, V355, P615
[15]   Speciation of organic selenium compounds by high-performance liquid chromatography inductively coupled plasma mass spectrometry in natural samples [J].
Olivas, RM ;
Donard, OFX ;
Gilon, N ;
PotinGautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1171-1176
[16]   ANALYTICAL TECHNIQUES APPLIED TO THE SPECIATION OF SELENIUM IN ENVIRONMENTAL MATRICES [J].
OLIVAS, RM ;
DONARD, OFX ;
CAMARA, C ;
QUEVAUVILLER, P .
ANALYTICA CHIMICA ACTA, 1994, 286 (03) :357-370
[17]   SELENIUM SPECIATION - A FLOW-INJECTION APPROACH EMPLOYING ONLINE MICROWAVE REDUCTION FOLLOWED BY HYDRIDE GENERATION-QUARTZ FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
PITTS, L ;
WORSFOLD, PJ ;
HILL, SJ .
ANALYST, 1994, 119 (12) :2785-2788
[18]   SELENIUM SPECIATION USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY HYDRIDE GENERATION ATOMIC FLUORESCENCE WITH ONLINE MICROWAVE REDUCTION [J].
PITTS, L ;
FISHER, A ;
WORSFOLD, P ;
HILL, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (08) :519-520
[19]   Determination of selenocystine, selenomethionine, selenite and selenate by high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry [J].
Quijano, MA ;
Gutierrez, AM ;
PerezConde, MC ;
Camara, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (06) :407-411
[20]   VESICLE-MEDIATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COUPLED TO ATOMIC DETECTION FOR SPECIATION OF TOXIC ELEMENTS [J].
SANZMEDEL, A ;
AIZPUN, B ;
MARCHANTE, JM ;
SEGOVIA, E ;
FERNANDEZ, ML ;
BLANCO, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 683 (01) :233-243