An Aortic Model for the Physiological Assessment of Endovascular Stent-Grafts

被引:3
作者
Desai, Mital [2 ]
Ahmed, Maqsood [1 ]
Darbyshire, Arnold [1 ]
You, Zhong [3 ]
Hamilton, George [1 ,2 ]
Seifalian, Alexander M. [1 ]
机构
[1] UCL, Div Surg & Intervent Sci, London NW3 2QG, England
[2] Royal Free Hampstead NHS Trust Hosp, Dept Vasc Surg, London, England
[3] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
基金
英国工程与自然科学研究理事会;
关键词
IN-VITRO; ELASTIC PROPERTIES; WALL COMPLIANCE; BYPASS GRAFT; DIAMETER; ARTERIES; ENDOTHELIALIZATION; STIFFNESS; ANEURYSMS; PRESSURE;
D O I
10.1016/j.avsg.2010.12.012
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background: The aim of this study was to manufacture a new aortic model with physiological properties, which could be used for long-term durability testing of endovascular stent-grafts, as per the recommendations of the Food and Drug Administration. Methods: Porcine abdominal aortas were acquired to establish values for compliance. The aortic model was manufactured using a nanocomposite polymer. Latex mock aorta was used for comparison. A pulsatile flow phantom perfused the aortas and synthetic tubes at physiological pulse pressure and flow. Diametrical compliance and stiffness index were calculated over mean pressures from 30 to 120 mm Hg. Data were analyzed using one-way analysis of variance and Bonferroni's test. Results: Flow circuit hemodynamic values were similar for porcine aorta and synthetic tubes. Compliance of aorta ranged from 2.97 +/- 0.72 (mean +/- SD) to 1.42 +/- 0.37%/mm Hg x 10(-2). The polymer model showed significantly better compliance (range, 3.66 +/- 1.05-2.72 +/- 0.28%/mm Hg x 10(-2); p < 0.05), with no significant difference in elastic stiffness index (range, 101.6 +/- 28.9-51.3 +/- 10.7 for aorta and 39.8 +/- 8.5-34.2 +/- 3.8 for polymer model; p > 0.05). It also showed anisotropic behavior similar to the aorta. Latex tubes showed compliance that was lower than that in aorta (range, 0.87 +/- 0.24-0.86 +/- 0.2%/mm Hg x 10(-2)) and failed by a significant distension on increase in pressure from mean of 90 mm Hg. Conclusions: We have developed physiologically relevant aortic model showing compatible anatomy, compliance, and viscoelasticity, which could be used for long-term fatigue analysis of vascular stents and grafts. The latex mock aortas can fail at physiological pressures.
引用
收藏
页码:530 / 537
页数:8
相关论文
共 31 条
[1]
EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]
[3]
Caro C.G., 1978, MECH CIRCULATION, P86
[4]
Engineering Silicone Rubbers for In Vitro Studies: Creating AAA Models and ILT Analogues With Physiological Properties [J].
Corbett, T. J. ;
Doyle, B. J. ;
Callanan, A. ;
Walsh, M. T. ;
McGloughlin, T. M. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (01)
[5]
In situ endothelialisation potential of a biofunctionalised nanocomposite biomaterial-based small diameter bypass graft [J].
de Mel, Achala ;
Punshon, Geoffrey ;
Ramesh, Bala ;
Sarkar, Sandip ;
Darbyshire, Arnold ;
Hamilton, George ;
Seifalian, Alexander M. .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2009, 19 (4-5) :317-331
[6]
Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro study [J].
Flecher, Erwan M. ;
Curry, John W. ;
Joudinaud, Thomas M. ;
Kegel, Corrine L. ;
Weber, Patricia A. ;
Duran, Carlos M. G. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (02) :291-294
[7]
Endotension is influenced by wall compliance in a latex aneurysm model [J].
Gawenda, M ;
Knez, P ;
Winter, S ;
Jaschke, G ;
Wassmer, G ;
Schmitz-Rixen, T ;
Brunkwall, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (01) :45-50
[8]
Effect of prolonged pulsatile shear stress in vitro on endothelial cell seeded PTFE and compliant polyurethane vascular grafts [J].
Giudiceandrea, A ;
Seifalian, AM ;
Krijgsman, B ;
Hamilton, G .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (02) :147-154
[9]
Giudiceandrea A., 2000, J ARTIF ORGANS, V3, P16
[10]
Noninvasive Assessment of Arterial Stiffness Should Discriminate Between Systolic and Diastolic Pressure Ranges [J].
Hermeling, Evelien ;
Hoeks, Arnold P. G. ;
Winkens, Mark H. M. ;
Waltenberger, Johannes L. ;
Reneman, Robert S. ;
Kroon, Abraham A. ;
Reesink, Koen D. .
HYPERTENSION, 2010, 55 (01) :124-130