Objective: Coronary flow obstruction is a serious complication reported in percutaneous aortic valve replacement. In an in vitro study of porcine hearts, the effects of valved stent implantation on coronary artery flow were studied with the native valve's leaflets intact and excised. Methods: The right and Left main coronary arteries of porcine hearts were dissected 20 mm distal. to the aortic root and directed into lengths of latex tubing leading to collection flasks. The ascending aorta was cut proximal to the brachiocephatic trunk, cannulated, and attached to a constant-head water supply. After steady flow was achieved, the flow rate from each coronary artery was measured. In Group A (n = 10), a tubular pericardial valve sutured into a cylindrical, cobalt-nickel stent was deployed orthotopically using a valvuloplasty, balloon catheter. In Group B (n = 10), the native leaflets were removed before similar valve deployment. Coronary flow measurements were repeated post-implantation. Results: In Group A, valve implantation resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after valve placement. Conclusion: Implantation of a percutaneous valved stent in the orthotopic position with the native valve in place causes coronary ostial obstruction. This problem highlights the need for modified stents that are designed for implantation in patients with non-retracted, fibrotic, or calcified leaflets. (C) 2007 European Association for Cardio-horacic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 294
页数:4
相关论文
共 12 条
[1]
TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[2]
Steps toward percutaneous aortic valve replacement [J].
Boudjemline, Y ;
Bonhoeffer, P .
CIRCULATION, 2002, 105 (06) :775-778
[3]
Choo SJ, 1999, J HEART VALVE DIS, V8, P407
[4]
Goetz WA, 2002, J HEART VALVE DIS, V11, P696
[5]
Grande K J, 1993, ASAIO J, V39, P918, DOI 10.1097/00002480-199310000-00017
[6]
Direct-access valve replacement - A novel approach for off-pump valve implantation using valved stents [J].
Huber, CH ;
Cohn, LH ;
von Segesser, LK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :366-370
[7]
A four-dimensional study of the aortic root dynamics [J].
Lansac, E ;
Lim, HS ;
Shomura, Y ;
Lim, KH ;
Rice, NT ;
Goetz, W ;
Acar, C ;
Duran, CMG .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) :497-503
[8]
Transapical transcatheter aortic valve implantation in humans - Initial clinical experience [J].
Lichtenstein, Samuel V. ;
Cheung, Anson ;
Ye, Jian ;
Thompson, Christopher R. ;
Carere, Ronald G. ;
Pasupati, Sanjeevan ;
Webb, John G. .
CIRCULATION, 2006, 114 (06) :591-596
[9]
Percutaneous aortic valve replacement: An experimental study. I. Studies on implantation [J].
Lutter, G ;
Kuklinski, D ;
Berg, G ;
von Samson, P ;
Martin, J ;
Handke, M ;
Uhrmeister, P ;
Beyersdorf, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :768-776
[10]
Percutaneous aortic valve replacement: resection before implantation [J].
Quaden, R ;
Attmann, T ;
Boening, A ;
Cremer, J ;
Lutter, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (05) :836-840