摘要
Two capillary zone electrophoretic (CZE) methods for determination of shikimic acid in Chilean red wine were developed and compared with a HPLC method. Both electrophoretic methods were carried out by using a reversed electroosmotic flow induced by trimethyl(tetradecyl)ammoniumbromide (TTAB) with indirect detection at 260 nm using p-aminobenzoic acid as a UV-absorbing co-ion or by direct detection at 213 nm. In both cases, the separation was carried out in a 50 mu m I.D. uncoated capillary with an effective length of 48 cm, a negative power supply of 30 kV, using a buffer based on bis[2-hydroxyethyl]imino-tris[hydroxymethyl]methane (Bis-Tris), pH 7.0 or 7.5 and hydrodynamic injection. The chromatographic separations were carried out on a C-18 reversed phase column followed by a sulfonyl-styrene-divinylbenzene (S-DVB) ion exclusion column at 70 degrees C with H2SO4 0.02M as isocratic mobile phase and a flow rate of 0.5 mL min(-1). The three methods allowed the quantification of shikimic acid with quantification limits between 1.0 and 12.0 mg L-1 and precision between 7.3 and 10.1%, however, only the concentrations obtained by CZE with direct detection were statistically similar to those of HPLC. This parameter was evaluated as analytical tool to verify varietal authenticity of red wines. In all cases, the Cabernet Sauvignon wines presented higher concentrations of shikimic acid, compared with Merlot or Carmenere wines. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:285 / 292
页数:8
相关论文
共 27 条
[1]  
BORDEU E, 1998, ANAL QUIMICO VINO
[2]   Glyphosate applied preharvest induces shikimic acid accumulation in hard red spring wheat (Triticum aestivum) [J].
Bresnahan, GA ;
Manthey, FA ;
Howatt, KA ;
Chakraborty, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (14) :4004-4007
[3]   Analysis of organic acids in wine by capillary electrophoresis with direct UV detection [J].
Castiñeira, A ;
Peña, RM ;
Herrero, C ;
García-Martín, S .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2002, 15 (03) :319-331
[4]   Simultaneous determination of organic acids, sugars, and alcohols in musts and wines by an improved ion-exclusion HPLC method [J].
Chinnici, F ;
Spinabelli, U ;
Amati, A .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (16) :2551-2560
[5]   Determination of carboxylic acids in vinegars and in Aceto Balsamico Tradizionale di Modena by HPLC and GC methods [J].
Cocchi, M ;
Lambertini, P ;
Manzini, D ;
Marchetti, A ;
Ulrici, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (19) :5255-5261
[6]   The surface properties of tetradecyltrimethylammonium bromide observed by capillary electrophoresis [J].
Cocke, DL ;
Schennach, R ;
Yu, ZH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (04) :187-190
[7]   Stir bar sorptive extraction-liquid desorption applied to the analysis of hop-derived bitter acids in beer by micellar electrokinetic chromatography [J].
De Villiers, A ;
Vanhoenacker, G ;
Lynen, F ;
Sandra, P .
ELECTROPHORESIS, 2004, 25 (4-5) :664-669
[8]   A robust capillary electrophoresis method for the determination of organic acids in wines [J].
de Villiers, A ;
Lynen, F ;
Crouch, A ;
Sandra, P .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2003, 217 (06) :535-540
[9]   Analysis of organic acids and inorganic anions in beverage drinks by capillary electrophoresis [J].
Fung, YS ;
Lau, KM .
ELECTROPHORESIS, 2003, 24 (18) :3224-3232
[10]  
Holbach B., 2001, Lebensmittelchemie, V55, P32