Detection of vathoizen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors

被引:66
作者
Rijal, K
Leung, A
Shankar, PM
Mutharasan, R [1 ]
机构
[1] Drexel Univ, Dept Chem Engn, Philadelphia, PA 19104 USA
[2] Drexel Univ, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
biosensor; selectivity; kinetics; fiber-optics;
D O I
10.1016/j.bios.2005.02.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Optical fibers (core diameter 8 mu m, cladding diameter 125 mu m) was tapered to a waist diameter in the range of 8-12 mu m, and then a monoclonal antibody to the pathogen, Escherichia coli O157:H7 was covalently bonded to the surface of the tapered region. Using 470 nm light, the taper was exposed to various concentrations (7 x 10(7), 7 x 10(5) 7 x 10(3), and 70 cells/mL) of the pathogen, and the sensor showed changes in transmitted light as the antigen attached to the antibody on the taper surface. The response was equal and opposite when the pathogen was released from the surface using a low pH buffer. The magnitude of the change was inversely proportional to the concentration of the pathogen. The sensor showed good sensitivity at as low a concentration as 70 cells/mL. The antibody-inn mobilized taper sensor was also exposed to a mixture of the pathogen and a non-pathogenic variant (JM101) at 0%, 50% and 70% by concentration. The sensor showed good selectivity to the pathogenic antigen. A first order attachment kinetic model is proposed to quantify the rate of attachment of pathogen to the sensor surface. The kinetic rate constant (k) of E. coli O157:H7 to the fiber was found to vary in the range of (2.5-6.1) x 10(-9) min(-1) (cells/mL)(-1). (c) 2005 Elsevier B.V. All fights reserved.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 25 条
[1]   A fibre-optic biosensor for detection of microbial contamination [J].
Almadidy, A ;
Watterson, J ;
Piunno, PAE ;
Foulds, IV ;
Horgen, PA ;
Krull, U .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 2003, 81 (05) :339-349
[2]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[3]   Optical fiber strain gauge based on a tapered single-mode fiber [J].
Arregui, FJ ;
Matías, IR ;
López-Amo, M .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 79 (02) :90-96
[4]   BENDING EFFECTS IN BICONICALLY TAPERED SINGLE-MODE FIBERS [J].
BOBB, LC ;
SHANKAR, PM ;
KRUMBOLTZ, HD .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1990, 8 (07) :1084-1090
[5]  
CAMPBELL GA, IN PRESS DETECTION
[6]  
CHUNGTUNG JL, IN PRESS FOOD QUAL P
[7]   Fiber grating spectra [J].
Erdogan, T .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1997, 15 (08) :1277-1294
[8]   Development of an evanescent-field fibre optic sensor for Escherichia coli O157:H7 [J].
Ferreira, AP ;
Werneck, MM ;
Ribeiro, RM .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) :399-408
[9]   Fabrication of biconical tapered optical fibers using hydrofluoric acid [J].
Haddock, HS ;
Shankar, PM ;
Mutharasan, R .
MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 2003, 97 (01) :87-93
[10]   Evanescent sensing of biomolecules and cells [J].
Haddock, HS ;
Shankar, PM ;
Mutharasan, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (01) :67-74