Wearable temporary tattoo sensor for real-time trace metal monitoring in human sweat

被引:191
作者
Kim, Jayoung [1 ]
de Araujo, William R. [1 ,2 ]
Samek, Izabela A. [1 ]
Bandodkar, Amay J. [1 ]
Jia, Wenzhao [1 ]
Brunetti, Barbara [1 ,3 ]
Paixao, Thiago R. L. C. [2 ]
Wang, Joseph [1 ]
机构
[1] Univ Calif San Diego, Dept Nanoengn, La Jolla, CA 92093 USA
[2] Univ Sao Paulo, Inst Quim, BR-05508000 Sao Paulo, Brazil
[3] Univ Milan, DeFENS, I-20133 Milan, Italy
基金
巴西圣保罗研究基金会;
关键词
Wearable sensors; Stripping voltammetry; Zinc; Temporary tattoo sensor; Sweat; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH ELECTRODES; ZINC; SERUM; LEAD; EXERCISE; COPPER;
D O I
10.1016/j.elecom.2014.11.024
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A wearable electrochemical sensor for non-invasive monitoring of trace metals in human perspiration is described. The temporary tattoo-based printable stripping-voltammetric sensor has been applied for real-time monitoring of zinc in sweat using a bismuth/Nafion film electrode during physical activity. The Zn temporary tattoo sensor withstands repeated mechanical stress and displays a well-defined Zn response during on-body testing. Such a non-invasive stripping-voltammetric detection could be readily expanded to epidermal measurements of other relevant heavy metals. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 45
页数:5
相关论文
共 28 条
[11]   Wireless sensor networks and chemo-/biosensing [J].
Diamond, Dermot ;
Coyle, Shirley ;
Scarmagnani, Silvia ;
Hayes, Jer .
CHEMICAL REVIEWS, 2008, 108 (02) :652-679
[12]   Zinc supplementation in critically ill patients: A key pharmaconutrient? [J].
Heyland, Daren K. ;
Jones, Naorni ;
Cvijanovich, Natalie Z. ;
Wong, Hector .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2008, 32 (05) :509-519
[13]   Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration [J].
Jia, Wenzhao ;
Bandodkar, Amay J. ;
Valdes-Ramirez, Gabriela ;
Windmiller, Joshua R. ;
Yang, Zhanjun ;
Ramirez, Julian ;
Chan, Garrett ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2013, 85 (14) :6553-6560
[14]   Zinc Detection in Serum by Anodic Stripping Voltammetry on Microfabricated Bismuth Electrodes [J].
Jothimuthu, Preetha ;
Wilson, Robert A. ;
Herren, Josi ;
Pei, Xing ;
Kang, Wenjing ;
Daniels, Rodney ;
Wong, Hector ;
Beyette, Fred ;
Heineman, William R. ;
Papautsky, Ian .
ELECTROANALYSIS, 2013, 25 (02) :401-407
[15]   Lab-on-a-Chip Sensor with Evaporated Bismuth Film Electrode for Anodic Stripping Voltammetry of Zinc [J].
Kang, Wenjing ;
Pei, Xing ;
Yue, Wei ;
Bange, Adam ;
Heineman, William R. ;
Papautsky, Ian .
ELECTROANALYSIS, 2013, 25 (12) :2586-2594
[16]  
Kim DH, 2012, ANNU REV BIOMED ENG, V14, P113, DOI [10.1146/annurev-bioeng-071811-150018, 10.1146/annurev.bioeng-071811-150018]
[17]   EFFECT OF EXERCISE ON SERUM ENZYME-ACTIVITIES IN HUMANS [J].
NOAKES, TD .
SPORTS MEDICINE, 1987, 4 (04) :245-267
[18]   TRACE-ELEMENTS IN THE SWEAT OF ACCLIMATIZED PERSONS [J].
OMOKHODION, FO ;
HOWARD, JM .
CLINICA CHIMICA ACTA, 1994, 231 (01) :23-28
[19]   THE DETERMINATION OF TRACE-METALS IN SWEAT BY ANODIC-STRIPPING VOLTAMMETRY [J].
STAUBER, JL ;
FLORENCE, TM .
SCIENCE OF THE TOTAL ENVIRONMENT, 1987, 60 :263-271
[20]   A COMPARATIVE-STUDY OF COPPER, LEAD, CADMIUM AND ZINC IN HUMAN SWEAT AND BLOOD [J].
STAUBER, JL ;
FLORENCE, TM .
SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 74 :235-247