Broad-spectrum separations in metabolomics using enhanced polar LC stationary phases: A dedicated evaluation using plant metabolites

被引:8
作者
t'Kindt, Ruben
Alaerts, Goedele
Heyden, Yvan Vander
Deforce, Dieter
Van Bocxlaer, Jan
机构
[1] Univ Ghent VIB, Lab Med Biochem & Clin Analysis, Ghent, Belgium
[2] Vrije Univ Brussels, Brussels, Belgium
[3] Univ Ghent VIB, Lab Pharmaceut Biotechnol, Ghent, Belgium
关键词
extended polarity reversed-phase material; mass spectrometry; microliquid chromatography; plant metabolomics;
D O I
10.1002/jssc.200700077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In metabolomics, major efforts are invested in the development of suitable analytical approaches. A tendency towards the use of LC-MS is nowadays very obvious. A great majority of the metabolites of interest are polar to highly polar in nature. We focus on the so-called 'extended polarity' reversed LC phases, developed specifically to allow better retention characteristics for polar compounds. Several of these phases (Atlantis dC18, Inertsil ODS-3, Zorbax XDB, Alltima HP C18) are tested for different column dimension variations (0.5, 1.0, 2.1 mm id) in a specific LC-MS metabolomics setting. Important chromatographic and mass spectrometric quality parameters such as capacity factor, separation efficiency, peak symmetry, sensitivity, and mass accuracy are taken into account. All phases show adequate retention of polar compounds and also perform well with highly aqueous mobile phase compositions. On comparing 1.0 and 2.1 mm id columns, it is clear that the potential gain in sensitivity is not achieved. Using a Lockspray (R) device, accurate mass measurement with a Q-TOF micro is feasible within a mass range of 12 ppm if signal intensities of compound and lockmass are equated. Finally, the extended polarity RP approach in metabolomics experiments is endorsed using real plant extracts.
引用
收藏
页码:2002 / 2011
页数:10
相关论文
共 24 条
[1]   Can protonated β-blockers interact with biomembranes stronger than neutral isolipophilic compounds?: A chromatographic study on three different phospholipid stationary phases (IAM-HPLC) [J].
Barbato, F ;
di Martino, G ;
Grumetto, L ;
La Rotonda, MI .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2005, 25 (4-5) :379-386
[2]   Potential of metabolomics as a functional genomics tool [J].
Bino, RJ ;
Hall, RD ;
Fiehn, O ;
Kopka, J ;
Saito, K ;
Draper, J ;
Nikolau, BJ ;
Mendes, P ;
Roessner-Tunali, U ;
Beale, MH ;
Trethewey, RN ;
Lange, BM ;
Wurtele, ES ;
Sumner, LW .
TRENDS IN PLANT SCIENCE, 2004, 9 (09) :418-425
[3]   High-performance liquid chromatography with non-aqueous solvents - Relative elution strength on a polystyrene-divinylbenzene column [J].
Chambers, TK ;
Fritz, JS .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :271-278
[4]   A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer [J].
Colombo, M ;
Sirtori, FR ;
Rizzo, V .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :511-517
[5]   Metabolite profiling for plant functional genomics [J].
Fiehn, O ;
Kopka, J ;
Dörmann, P ;
Altmann, T ;
Trethewey, RN ;
Willmitzer, L .
NATURE BIOTECHNOLOGY, 2000, 18 (11) :1157-1161
[6]   Deciphering metabolic networks [J].
Fiehn, O ;
Weckwerth, W .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 2003, 270 (04) :579-588
[7]   Plant meta-bolomics: Potential for practical operation [J].
Fukusaki, E ;
Kobayashi, A .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2005, 100 (04) :347-354
[8]   Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response assessment [J].
Gaudin, K ;
Baillet, A ;
Chaminade, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) :43-51
[9]   Multidimensional separations in the pharmaceutical arena [J].
Guttman, A ;
Varoglu, M ;
Khandurina, J .
DRUG DISCOVERY TODAY, 2004, 9 (03) :136-144
[10]   Processing methods for differential analysis of LC/MS profile data [J].
Katajamaa, M ;
Oresic, M .
BMC BIOINFORMATICS, 2005, 6 (1)