Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response assessment

被引:23
作者
Gaudin, K [1 ]
Baillet, A [1 ]
Chaminade, P [1 ]
机构
[1] Fac Pharm Chatenay Malabry, Grp Chim Analyt Paris Sud, EA 3343, Chim Analyt Lab, F-92290 Chatenay Malabry, France
关键词
evaporative light-scattering detection; detection; LC; calibration; instrumentation; lipids;
D O I
10.1016/j.chroma.2004.05.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A commercially available evaporative light-scattering detection (ELSD) system was adapted for micro and capillary LC. Therefore the various parameters involved in the droplet formation during the nebulization step in the ELSD system were studied. It was shown that the velocity term in the Nukiyama Tanasawa equation remains constant, leading to droplets of the same order of magnitude for narrow bore and capillary columns. Consequently, the ELSD modification was performed by decreasing the internal diameter of the effluent capillary tube in the nebulizer nozzle and by keeping its external diameter constant. Next, response curves for a conventional and the developed micro and capillary LC were compared as to investigate why a linear ELSD response is often obtained when used in micro or capillary LC. By splitting the flow rate post column, we showed that the nebulization process was not at the origin of the phenomenon. For ceramide III and tripalmitin, the response curves were found to be non-linear. However the curvature was less significant when the columns internal diameter decreased. Calculated particle size profiles for micro or capillary LC suggest that the particle entering the detection chamber are bigger than under conventional LC conditions. Last, triethylamine and formic acid were used to increase the response of the detector. The response enhancement, expected from previous studies, was established for the two lipids involved in this study. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 23 条
[1]  
Alexander JN, 1998, J MICROCOLUMN SEP, V10, P491, DOI 10.1002/(SICI)1520-667X(1998)10:6<491::AID-MCS4>3.0.CO
[2]  
2-B
[3]  
Andersson MBO, 1998, J MICROCOLUMN SEP, V10, P249, DOI 10.1002/(SICI)1520-667X(1998)10:3<249::AID-MCS2>3.3.CO
[4]  
2-J
[5]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[6]  
CHERVET JP, 1992, LC GC EUR, V5, P33
[7]   Evaporative light-scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: Sensitivity, linearity of response and comparisons with UV absorbance detection [J].
Cobb, Z ;
Shaw, PN ;
Lloyd, LL ;
Wrench, N ;
Barrett, DA .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (04) :169-175
[8]   Mechanism of response enhancement in evaporative light scattering detection with the addition of triethylamine and formic acid [J].
Deschamps, FS ;
Baillet, A ;
Chaminade, P .
ANALYST, 2002, 127 (01) :35-41
[9]   Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species [J].
Deschamps, FS ;
Gaudin, K ;
Lesellier, E ;
Tchapla, A ;
Ferrier, D ;
Baillet, A ;
Chaminade, P .
CHROMATOGRAPHIA, 2001, 54 (9-10) :607-611
[10]  
Dreux M., 1996, LC GC INTERNATIONAL, V9, P148