Evaluation of a new IOLMaster algorithm to measure axial length

被引:67
作者
Hill, Warren [1 ]
Angeles, Raymund [1 ]
Otani, Todd [1 ]
机构
[1] Carl Zeiss Meditec Inc, Dublin, CA 94568 USA
关键词
D O I
10.1016/j.jcrs.2008.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: To evaluate the ability of the new IOLMaster with Advanced Technology version 5 software (Carl Zeiss Meditec, AG) to measure axial length (AL) in patients having preoperative cataract extraction evaluation. SETTING: Private practice, Arizona, USA. METHODS: This single-center study comprised 54 eyes (33 patients) scheduled for cataract extraction. Visual acuity, manifest refraction, and Lens Opacities Classification System III (LOCS III) scores were recorded. Twenty AL measurements per eye were acquired using an IOLMaster with Advanced Technology version 5 software. The AL measurements were analyzed and classified into 4 methods: standard, standard manipulated, composite-5, and composite-20. RESULTS: Axial length measurements were successfully obtained in 55.6%, 94.4%, 92.6%, and 96.3% of eyes with the standard, standard manipulated, composite-5, and composite-20 methods, respectively. Axial length measurement availability (ability of the software to provide an AL measurement) was not statistically significantly affected by nuclear color, nuclear opalescence, or cortical changes with any method. However, posterior subcapsular changes statistically significantly affected the standard and composite methods (P <.05) and marginally affected the standard manipulated method in measuring the AL (P = .0868). Axial length availability was significantly reduced in eyes with posterior subcapsular cataract of LOCS III grade 5.0 or higher. CONCLUSIONS: The 2 composite methods performed as well as the more time consuming, complicated standard manipulated method in measuring AL. More than 90% of eyes could be measured by the composite methods. Dense posterior subcapsular cataracts significantly reduced the ability of the composite and standard manipulated methods to Successfully measure AL.
引用
收藏
页码:920 / 924
页数:5
相关论文
共 20 条
[1]
THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[2]
Accuracy and reproducibility of biometry using partial coherence interferometry [J].
Connors, R ;
Boseman, P ;
Olson, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :235-238
[3]
Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[4]
IOLMaster biometry: refractive results of 100 consecutive cases [J].
Eleftheriadis, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (08) :960-963
[5]
Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery [J].
Findl, O ;
Kriechbaum, K ;
Sacu, S ;
Kiss, B ;
Polak, K ;
Nepp, J ;
Schild, G ;
Rainer, G ;
Maca, S ;
Petternel, V ;
Lackner, B ;
Drexler, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10) :1950-1955
[6]
The impact of cataract severity on measurement acquisition with the IOLMaster [J].
Freeman, G ;
Pesudovs, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (04) :439-442
[7]
Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[8]
Hill W.E., 2003, TECH OPHTHALMOL, V1, P62
[9]
Biometry of cataractous eyes using partial coherence interferometry - Clinical feasibility study of a commercial prototype I [J].
Kiss, B ;
Findl, O ;
Menapace, R ;
Wirtitsch, M ;
Drexler, W ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :224-229
[10]
Refractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometry - Clinical feasibility study of a commercial prototype II [J].
Kiss, B ;
Findl, O ;
Menapace, R ;
Wirtitsch, M ;
Petternel, V ;
Drexler, W ;
Rainer, G ;
Georgopoulos, M ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :230-234