FT-ICR mass spectrometry in the drug discovery process

被引:30
作者
Zhang, J [1 ]
McCombie, G [1 ]
Guenat, C [1 ]
Knochenmuss, R [1 ]
机构
[1] Novartis Inst Biomed Res, CH-4056 Basel, Switzerland
关键词
D O I
10.1016/S1359-6446(05)03438-0
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The high mass accuracy and resolution of Fourier transform (FT)-ion cyclotron resonance (ICR) mass spectrometry are making it an increasingly useful tool in drug discovery and development. The basics of FT-ICR are described here, including modern ion sources and fragmentation methods. Although FT-ICR is not a high-throughput method in the traditional sense, previously difficult and complex problems are being efficiently approached using steadily improving instruments and magnets. Applications are surveyed in fields such as proteomics, metabonomics, natural product analysis and non-covalent complexes.
引用
收藏
页码:635 / 642
页数:8
相关论文
共 82 条
[1]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[2]  
Baykut G, 2000, RAPID COMMUN MASS SP, V14, P1238, DOI 10.1002/1097-0231(20000730)14:14<1238::AID-RCM17>3.0.CO
[3]  
2-H
[4]   A combined ion source for fast switching between electrospray and matrix-assisted laser desorption ionization in Fourier transform ion cyclotron resonance mass spectrometry [J].
Baykut, G ;
Fuchser, J ;
Witt, M ;
Weiss, G ;
Gosteli, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (17) :1631-1641
[5]   Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance [J].
Belov, ME ;
Zhang, R ;
Strittmatter, EF ;
Prior, DC ;
Tang, K ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4195-4205
[6]   An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics [J].
Belov, ME ;
Anderson, GA ;
Wingerd, MA ;
Udseth, HR ;
Tang, KQ ;
Prior, DC ;
Swanson, KR ;
Buschbach, MA ;
Strittmatter, EF ;
Moore, RJ ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (02) :212-232
[7]   Peptide mapping of proteins in human body fluids using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Bergquist, J ;
Palmblad, M ;
Wetterhall, M ;
Håkansson, P ;
Markides, KE .
MASS SPECTROMETRY REVIEWS, 2002, 21 (01) :2-15
[8]  
Bergquist J, 2003, CURR OPIN MOL THER, V5, P310
[9]  
BOURNE DJ, 1998, ADV MASS SPECTROM
[10]   An automated matrix-assisted laser desorption/ionization quadrupole Fourier transform ion cyclotron resonance mass spectrometer for "bottom-up" proteomics [J].
Brock, A ;
Horn, DM ;
Peters, EC ;
Shaw, CM ;
Ericson, C ;
Phung, QT ;
Salomon, AR .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3419-3428