Silicon drift detectors for high count rate X-ray spectroscopy at room temperature

被引:191
作者
Lechner, P
Fiorini, C
Hartmann, R
Kemmer, J
Krause, N
Leutenegger, P
Longoni, A
Soltau, H
Stötter, D
Stötter, R
Strüder, L
Weber, U
机构
[1] KETEK GmbH, D-85764 Oberschleissheim, Germany
[2] Max Planck Inst Extraterr Phys, D-81739 Munich, Germany
[3] Politecn Milan, I-20122 Milan, Italy
关键词
silicon drift detector; X-ray spectroscopy; X-ray detector; gamma-camera;
D O I
10.1016/S0168-9002(00)00872-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon Drift Detectors (SDDs) combine a large sensitive area with a small value of the output capacitance and are therefore well suited for high resolution, high count rate X-ray spectroscopy. The low leakage current level obtained by the elaborated processing technology makes it possible to operate them at room temperature or with moderate cooling. A brief description of the device principle is followed by the presentation of first results of a new production of large area SDDs with external electronics. Performance and applications of the already established SDDs with on-chip amplification are summarised. Various shapes of Multichannel Drift Detectors are introduced as well as their use in new experiments like X-ray holography and in new systems like an Anger camera for gamma -ray imaging. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 15 条
[1]   First experimental results of a new gamma-ray detector based on a Silicon Drift Chamber coupled to a scintillator [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :395-399
[2]   Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2553-2560
[3]  
FIORINI C, 1999, IN PRESS IEEE T NS
[4]   SEMICONDUCTOR DRIFT CHAMBER - AN APPLICATION OF A NOVEL CHARGE TRANSPORT SCHEME [J].
GATTI, E ;
REHAK, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03) :608-614
[5]   SILICON DRIFT CHAMBER PROTOTYPE-STAR FOR THE UPGRADE OF THE UA6 EXPERIMENT AT THE CERN PPBAR COLLIDER [J].
GATTI, E ;
LONGONI, A ;
SAMPIETRO, M ;
GIACOMELLI, P ;
VACCHI, A ;
REHAK, P ;
KEMMER, J ;
HOLL, P ;
STRUDER, L ;
KUBISCHTA, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3) :865-868
[6]   High resolution, 6 channels, silicon drift detector array with integrated JFET's designed for XAFS spectroscopy: First X-ray fluorescence excitation spectra recorded at the ESRF [J].
Gauthier, C ;
Goulon, J ;
Moguiline, E ;
Rogalev, A ;
Lechner, P ;
Struder, L ;
Fiorini, C ;
Longoni, A ;
Sampietro, M ;
Besch, H ;
Pfitzner, R ;
Schenk, H ;
Tafelmeier, U ;
Walenta, A ;
Misiakos, K ;
Kavadias, S ;
Loukas, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03) :524-532
[7]   Low energy response of silicon pn-junction detector [J].
Hartmann, R ;
Hauff, D ;
Lechner, P ;
Richter, R ;
Struder, L ;
Kemmer, J ;
Krisch, S ;
Scholze, F ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :191-196
[8]  
HARTMANN R, 1997, NIMA, V387, P241
[9]   A 55 cm(2) cylindrical silicon drift detector [J].
Holl, P ;
Rehak, P ;
Ceretto, F ;
Faschingbauer, U ;
Wurm, JP ;
Castoldi, A ;
Gatti, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :367-374
[10]   LOW CAPACITY DRIFT DIODE [J].
KEMMER, J ;
LUTZ, G ;
BELAU, E ;
PRECHTEL, U ;
WELSER, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03) :378-381