Cerebral perfusion imaging using contrast-enhanced MRI

被引:43
作者
Keston, P
Murray, AD
Jackson, A
机构
[1] Acad Dept Radiol, Aberdeen AB25, Scotland
[2] Univ Manchester, Dept Med, Manchester M13 9PL, Lancs, England
关键词
magnetic resonance imaging; haemodynamics; contrast media; brain;
D O I
10.1016/S0009-9260(03)00130-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
New developments in fast magnetic resonance imaging (MRI) have enabled imaging of cerebral haemodynamics. This article describes the theory behind perfusion imaging and provides an overview of the most commonly used MRI technique. Limitations of this technique are described, and the potential clinical applications are discussed, with particular attention to the role of perfusion imaging in the context of stroke and brain tumour. (C) 2003 The Royal College of Radiologists. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:505 / 513
页数:9
相关论文
共 87 条
[1]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[2]   Methodology of brain perfusion imaging [J].
Barbier, EL ;
Lamalle, L ;
Décorps, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :496-520
[3]  
BELLIVEAU JW, 1989, 8 ANN M SOC MAGN RES, P63
[4]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[5]   Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies [J].
Boxerman, JL ;
Rosen, BR ;
Weisskoff, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :528-537
[6]  
Bozzao A, 2001, AM J NEURORADIOL, V22, P1030
[7]   DYNAMIC IMAGING OF CONTRAST ENHANCEMENT IN BRAIN-TUMORS [J].
BULLOCK, PR ;
MANSFIELD, P ;
GOWLAND, P ;
WORTHINGTON, BS ;
FIRTH, JL .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :293-298
[8]   Measuring cerebral blood flow using magnetic resonance imaging techniques [J].
Calamante, F ;
Thomas, DL ;
Pell, GS ;
Wiersma, J ;
Turner, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07) :701-735
[9]   Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke - Assumptions, limitations, and potential implications for clinical use [J].
Calamante, F ;
Gadian, DG ;
Connelly, A .
STROKE, 2002, 33 (04) :1146-1151
[10]   MR perfusion imaging in moyamoya syndrome - Potential implications for clinical evaluation of occlusive cerebrovascular disease [J].
Calamante, F ;
Ganesan, V ;
Kirkham, FJ ;
Jan, W ;
Chong, WK ;
Gadian, DG ;
Connelly, A .
STROKE, 2001, 32 (12) :2810-2816